2015
DOI: 10.1016/j.ijom.2015.01.011
|View full text |Cite
|
Sign up to set email alerts
|

Ultralow-dose computed tomography imaging for surgery of midfacial and orbital fractures using ASIR and MBIR

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
39
0
2

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 30 publications
(41 citation statements)
references
References 27 publications
0
39
0
2
Order By: Relevance
“…Compared with a reference protocol at a CTDI vol of 35.3 mGy, the use of protocols with a CTDI vol of 1.0 and 2.6 mGy may be sufficient for the diagnosis of dislocated and non-dislocated craniofacial fractures, respectively. 7 Compared In the present study, a low-dose sinusitis protocol at CTDI vol of 18.28 mGy and several ultralow dose protocols at CTDI vol 4.14, 2.63, 0.99 and 0.53 mGy were evaluated in terms of HU stability and CNR. Compared with the reference protocol at CTDI vol of 36.58 mGy, the low-dose sinusitis protocol had a radiation exposure of only 50%, and the subsequent ultralow dose protocols I-IV have exposures of 11%, 7%, 3% and 1.5%, respectively.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Compared with a reference protocol at a CTDI vol of 35.3 mGy, the use of protocols with a CTDI vol of 1.0 and 2.6 mGy may be sufficient for the diagnosis of dislocated and non-dislocated craniofacial fractures, respectively. 7 Compared In the present study, a low-dose sinusitis protocol at CTDI vol of 18.28 mGy and several ultralow dose protocols at CTDI vol 4.14, 2.63, 0.99 and 0.53 mGy were evaluated in terms of HU stability and CNR. Compared with the reference protocol at CTDI vol of 36.58 mGy, the low-dose sinusitis protocol had a radiation exposure of only 50%, and the subsequent ultralow dose protocols I-IV have exposures of 11%, 7%, 3% and 1.5%, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…[4][5][6] It is not commonly known that recent CT technology allows high-resolution protocols at dose exposition equal or lower than CBCT (5 ultralow dose CT). 7,8 To reduce the increase of noise in ultralow dose imaging, iterative reconstruction technologies (IRTs) such as adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) have been implemented with promising potential. 8,9 To the best of the authors' knowledge, this is the first study that aimed to evaluate whether application of ultralow dose protocols and IRT influence HU and contrast-to-noise ratio (CNR), with a specific focus on dentomaxillofacial CT imaging.…”
Section: Introductionmentioning
confidence: 99%
“…The consensus across the literature is that MDCT is the imaging modality of choice for adult patients with complex facial bone trauma . The liberal use of MDCT has become a concern because the ED exceeds that of plain radiography at an average of 1.5–2.9 mSv per facial bone CT compared to 0.02–0.1 mSv for x‐ray .…”
Section: Discussionmentioning
confidence: 99%
“…The results are confirmed by a cadaver study, which showed that the detection rate of maxillofacial fractures could not be improved by use of IRT. 10 When comparing the RP and FBP as the clinical reference with the other combinations, LD-I and II using MBIR were able to show comparable scores at a dose reduction of up to 93%.…”
mentioning
confidence: 93%
“…8,9 However, IRT images reportedly demonstrate an "oversmoothing" effect which may interfere with the need for a high spatial accuracy in dentomaxillofacial imaging. 8,10 Therefore, the aim of the study was to assess how IRT influences contrast and spatial resolution in ultralow-dose CT.…”
Section: Introductionmentioning
confidence: 99%