2023
DOI: 10.1016/j.microc.2023.108444
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasensitive determination of metronidazole using flower-like cobalt anchored on reduced graphene oxide nanocomposite electrochemical sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(4 citation statements)
references
References 36 publications
0
4
0
Order By: Relevance
“…Stability is a crucial factor for electrochemical sensors used to detect drug molecules. 49 Thus, DPV was employed to investigate the stability of the sensor based on Ce-MOF/g-C 3 N 5 . First, the GCE modified by the Ce-MOF/g-C 3 N 5 composite was constructed and stored in a refrigerator at −4 °C.…”
Section: Resultsmentioning
confidence: 99%
“…Stability is a crucial factor for electrochemical sensors used to detect drug molecules. 49 Thus, DPV was employed to investigate the stability of the sensor based on Ce-MOF/g-C 3 N 5 . First, the GCE modified by the Ce-MOF/g-C 3 N 5 composite was constructed and stored in a refrigerator at −4 °C.…”
Section: Resultsmentioning
confidence: 99%
“…The most outstanding results in terms of analytical performance were recorded using the sensors based on gold nanoparticle carbon nanofiber (CNF@AuNPs/GCE), flower-like cobalt anchored on reduced graphene oxide (f-Co@rGO/GCE), silver nanoparticles decorated graphene oxide (GO@AgNPs-GCE), graphene nanoplatelets and bismuth (GCE/Gr/Bi), carbon nanofibers supported with Ni−Co layered double hydroxide (CNF-NiCo-LDH/GCE), and graphene magnetite nanoparticles (GR/Fe 3 O 4 NPs/GCE). [88][89][90][91][92][93] The effectiveness of combining several modifiers is evident in achieving enhanced outcomes.…”
Section: Electrochemical Sensors Used For the Determination Of Topica...mentioning
confidence: 99%
“…The use of GPHOx was necessary because graphene derivatives with higher conductivity are more difficult to solubilize in aqueous medium and it would be difficult to obtain a homogeneous and stable suspension in the chitosan solution. In practice, after modifying the electrodes with GPHOx, the surface undergoes an electrochemical reduction process [33], performed by CV. After the electrochemical reduction in 0.1 M PBS of pH 7.2, an important signal intensity increasing was observed, reaching 379 μA/-391 uA, with a peak-to-peak separation of 153 mV.…”
Section: Electrochemical Characterization Of the Sensors Based On Nan...mentioning
confidence: 99%