Comprehensive Biomedical Physics 2014
DOI: 10.1016/b978-0-444-53632-7.00217-3
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasound Imaging Modalities

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 111 publications
0
6
0
Order By: Relevance
“…The attenuation coefficient (a) is a frequencydependent parameter. Here, a was measured at seven (1:1:6 MHz, and 3.5 MHz) different frequencies according to (Mischi et al, 2014):…”
Section: Acoustic Measurementmentioning
confidence: 99%
See 1 more Smart Citation
“…The attenuation coefficient (a) is a frequencydependent parameter. Here, a was measured at seven (1:1:6 MHz, and 3.5 MHz) different frequencies according to (Mischi et al, 2014):…”
Section: Acoustic Measurementmentioning
confidence: 99%
“…where f is the frequency of the transmitted signal; A s and A w are the amplitudes of the frequency magnitude spectrum of the received signal in the presence of the sample and in water, respectively, and T is the transmission coefficient of the waves propagating through the front and rear surfaces of the sample, calculated as (Mischi et al, 2014):…”
Section: Acoustic Measurementmentioning
confidence: 99%
“…However, in the small driving pressure amplitude regime, the bubble behaves as a forced damped linear oscillator [56]. The radial motion of free bubbles can also be characterized in terms of variations in the liquid enthalpy, as described by the Gilmore equation [58], [59].…”
Section: Pharmacokinetic Modeling Of Contrast Agents For Quantitamentioning
confidence: 99%
“…and related the parameter A to the blood volume, and β to the blood velocity [58]. Blood flow is then represented by their product.…”
Section: Modelmentioning
confidence: 99%
“…We also considered testing the relative nonlinearity coefficient B/ A. This sensitive biomechanical property has long been utilized in ultrasonic imaging of blood and biomolecular imaging [26][27][28], as well as for quantitative non-destructive investigations [29]. The sequential variations of the three parameters are compared to their values at the beginning of the storage period, when the sample is fresh and ideal for transfusion and, therefore, can be regarded as the reference sample.…”
Section: Introductionmentioning