First-Trimester Ultrasound 2016
DOI: 10.1007/978-3-319-20203-7_1
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasound in the First Trimester and Earlier: How to Keep It Safe

Abstract: 1"Ultrasound is safe. Ultrasound is not X-rays. Our machines are FDA-approved." These are the statements most commonly made when initiating a conversation on safety of ultrasound. This is one of the reasons cited for its becoming an essential tool in medicine (together with its relatively low cost and immediate results availability). Diagnostic ultrasound (DUS) has been in use for over half a century in obstetrics and gynecology [1] and the benefits of this technology are multiple [2]. Most pregnant women have… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
14
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(14 citation statements)
references
References 140 publications
0
14
0
Order By: Relevance
“…The highest exposure intensity within the beam (i.e., spatial peak) is averaged over the time of exposure (i.e., temporal average) and is named the spatial peak temporal average. [6][7][8][9][10] After ultrasound manufacturers developed output display standard (ODS) biosafety measures by displaying their levels on the ultrasonic screens, the Food and Drug Agency (FDA) in 1992 deregulated the acoustic output levels of clinical ultrasound systems, which produced better images and therefore improved diagnosis for patients. Ultrasonic acoustic output levels, emitted by the transducer, for fetal, neonatal, and pediatric imaging were augmented from 94 mW/cm 2 in 1986 11 to 720 mW/cm 2 in 1992, 12 including the peak exposure through the mechanical index, which enhanced potential biophysical effects exerted on the embryo and fetus.…”
Section: History Of Pusmentioning
confidence: 99%
See 4 more Smart Citations
“…The highest exposure intensity within the beam (i.e., spatial peak) is averaged over the time of exposure (i.e., temporal average) and is named the spatial peak temporal average. [6][7][8][9][10] After ultrasound manufacturers developed output display standard (ODS) biosafety measures by displaying their levels on the ultrasonic screens, the Food and Drug Agency (FDA) in 1992 deregulated the acoustic output levels of clinical ultrasound systems, which produced better images and therefore improved diagnosis for patients. Ultrasonic acoustic output levels, emitted by the transducer, for fetal, neonatal, and pediatric imaging were augmented from 94 mW/cm 2 in 1986 11 to 720 mW/cm 2 in 1992, 12 including the peak exposure through the mechanical index, which enhanced potential biophysical effects exerted on the embryo and fetus.…”
Section: History Of Pusmentioning
confidence: 99%
“…Ultrasonic acoustic output levels, emitted by the transducer, for fetal, neonatal, and pediatric imaging were augmented from 94 mW/cm 2 in 1986 11 to 720 mW/cm 2 in 1992, 12 including the peak exposure through the mechanical index, which enhanced potential biophysical effects exerted on the embryo and fetus. 4,6,10,13 The ODS is composed of two indices to alert the end-user of temperature rise and mechanical impact. The soft tissue thermal index depends on three factors: transducer opening i.e.…”
Section: History Of Pusmentioning
confidence: 99%
See 3 more Smart Citations