2013
DOI: 10.1016/j.jemermed.2013.03.044
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasound of the Inferior Vena Cava Does Not Predict Hemodynamic Response to Early Hemorrhage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
31
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 48 publications
(38 citation statements)
references
References 16 publications
6
31
0
Order By: Relevance
“…Video clips lasting 10 s were recorded for off-line processing (as described above). The site chosen for the measurement was approximately 2 cm distal to the confluence of the hepatic vein (Juhl-Olsen et al 2013;Wallace et al 2010). In Figure 2, only translations of the vein are simulated (simulation 1 described earlier).…”
Section: Experimental Datamentioning
confidence: 99%
“…Video clips lasting 10 s were recorded for off-line processing (as described above). The site chosen for the measurement was approximately 2 cm distal to the confluence of the hepatic vein (Juhl-Olsen et al 2013;Wallace et al 2010). In Figure 2, only translations of the vein are simulated (simulation 1 described earlier).…”
Section: Experimental Datamentioning
confidence: 99%
“…12 limited by the diversity of methods, lack of validated measurements, technical difficulties in obese patients, the need for highly skilled operators, and the diversity in results obtained from different studied populations [11,19,20]. More importantly, in contrast to ultrasound assessment of FTc in the carotid artery, evaluation of inferior vena cava seems to be inaccurate in predicting volume status at the early stages of volume loss which is vital for the optimal approach to critically ill patients [11,19].…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…More importantly, in contrast to ultrasound assessment of FTc in the carotid artery, evaluation of inferior vena cava seems to be inaccurate in predicting volume status at the early stages of volume loss which is vital for the optimal approach to critically ill patients [11,19].…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…Muller et al [65] found that high variations in IVC diameter are associated with fluid responsiveness, but low variations do not exclude the fluid responsiveness emphasizing that the results should be interpreted carefully. On the other hand, Juhl-Olsen et al [66] did not find any change in IVC diameter in patients before and after the donation of blood. Since there are recent studies showing the high sensitivity and specificity of ultrasonographic evaluation of IVC collapse, it is definitely worth performing further investigations to clarify its effectiveness.…”
Section: Ivc Diametermentioning