Ultrasound velocity and attenuation of porcine soft tissues with respect to structure and composition: II. Skin and backfat

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
17
0
1

Year Published

2011
2011
2021
2021

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 30 publications
(20 citation statements)
references
References 31 publications
2
17
0
1
Order By: Relevance
“…Ultrasound images were evaluated interactively using an evaluation software (Rotosport, Austria; rotosport.at) for semiautomatic evaluations of SAT thicknesses. Sound speed was set to 1450 m s −1 for distance determination in fat [3,[18][19][20][21][22]. At each site, the software detects the SAT segments between the lower border of the skin and the upper border of the muscle fascia (for example, see Fig.…”
Section: Contour Detection and Sat Thickness Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…Ultrasound images were evaluated interactively using an evaluation software (Rotosport, Austria; rotosport.at) for semiautomatic evaluations of SAT thicknesses. Sound speed was set to 1450 m s −1 for distance determination in fat [3,[18][19][20][21][22]. At each site, the software detects the SAT segments between the lower border of the skin and the upper border of the muscle fascia (for example, see Fig.…”
Section: Contour Detection and Sat Thickness Measurementsmentioning
confidence: 99%
“…Diagnostic (brightness-mode) ultrasound has been used for fat measurement since 1965 [33,34], and many publications followed. At sufficiently high probe frequency (12)(13)(14)(15)(16)(17)(18), the thickness measurement accuracy is approximately 0.1-0.2 mm [3,6,35], provided that the appropriate speed of sound in the given tissue is used (1450 ms −1 in fat [18][19][20][21][22]). The high accuracy enables measuring the embedded fibrous structures, which amount to substantial percentages of the SAT (Fig.…”
Section: Ultrasound Brightness-mode Imaging and Distance Measurement mentioning
confidence: 99%
“…Due to their low fat levels we, therefore, suggest that skatole levels below 0.23 μg/g melted fat have no impact on the acceptance of lean pork. Furthermore, it is noteworthy that skatole values of about 0.23 μg/g melted fat correspond to approximately 0.17 μg/g fresh matter of backfat tissue since the fatty acid content in backfat has been reported to be about 75% (Koch et al, 2011). Furthermore, the inter-laboratory variation of skatole and androstenone analysis due to different sample preparation and detection techniques (Ampuero Kragten et al, 2011) has to be carefully considered when comparing thresholds for detection by trained assessors or consumer rejection.…”
Section: Taste and Overall Likingmentioning
confidence: 99%
“…Measurements of fat layers have been carried out with ultrasound and ultrasound imaging . However, no chemical information about the fat layers can be withdrawn from ultrasound measurements.…”
Section: Introductionmentioning
confidence: 99%