2015 IEEE 10th Conference on Industrial Electronics and Applications (ICIEA) 2015
DOI: 10.1109/iciea.2015.7334279
|View full text |Cite
|
Sign up to set email alerts
|

Unbalanced control of grid-side converter based on DSOGI-PLL

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 9 publications
0
5
0
Order By: Relevance
“…Addressing the imperative need for a precise and swift approximation of grid information within grid-tied PV systems, Phase-Locked Loop (PLL) schemes have been employed due to their recognized superiority in performance, as noted in [30]. The widely adopted DSOGI-PLL stands out for its structural simplicity, especially in three-phase grid synchronization, as corroborated in [30]. However, the conventional DSOGI-PLL grapples with substantial performance degradation under unbalanced grid conditions and distortions.…”
Section: Enhanced Dsogi-pllmentioning
confidence: 99%
See 1 more Smart Citation
“…Addressing the imperative need for a precise and swift approximation of grid information within grid-tied PV systems, Phase-Locked Loop (PLL) schemes have been employed due to their recognized superiority in performance, as noted in [30]. The widely adopted DSOGI-PLL stands out for its structural simplicity, especially in three-phase grid synchronization, as corroborated in [30]. However, the conventional DSOGI-PLL grapples with substantial performance degradation under unbalanced grid conditions and distortions.…”
Section: Enhanced Dsogi-pllmentioning
confidence: 99%
“…The performance of the algorithms is evaluated using three key metrics: Root Mean Squared Error (RMSE), Mean Absolute Error (MAE), and Mean Squared Error (MSE). These metrics, calculated using equations ( 28) to (30), provide quantitative measures of the algorithm's accuracy and effectiveness in predicting outcomes.…”
Section: A Case Study 1 -Fixed Tilt Approachmentioning
confidence: 99%
“…It is obvious from (11) that the control errors will diminish to zero and the references will be tracked provided that the estimation of f PQη is such that fPQη → f PQη , ∀ K PQη > 0.…”
Section: Control Formulationmentioning
confidence: 99%
“…The role of power converters is very unique since the converters are the interfaces enabling the synchronization, voltage control, current control and power flow control in the MG and SG [5,7,8]. A number of studies can be found in the literature regarding the control of three-phase VSI, specifically in view of controlling the imbalance of power in the MG [9][10][11][12][13]. All of these established works offer complexity, since they are designed to maintain pure sinusoidal voltages as the output of the VSI, whose conception dates back to the 1980s due to the stringent supply requirements of the three-phase motors [14][15][16][17].…”
mentioning
confidence: 99%
“…Based on the above, the positive and negative sequence decomposition link has become an important part of the wind farm control strategy. At present, the most common methods of phase-locked loop based on positive sequence components are the dual second-order, generalised integrator phase-locked loop (DSOGI-PLL) [6], and the decoupled double synchronous reference frame phase-locked loop (DDSRF-PLL) [7]. Compared with DSOGI-PLL, the algorithm structure of DDSRF-PLL is more complex, and the decoupling structure of DDSRF-PLL is mainly aimed at eliminating the infuence of the negative sequence fundamental frequency component, while the ability to resist low harmonic disturbance is relatively weak [8,9].…”
Section: Introductionmentioning
confidence: 99%