Uncertainty Estimates of Purity Measurements Based on Current Information: Toward a “Live Validation” of Purity Methods

Abstract: PurposeTo predict precision and other performance characteristics of chromatographic purity methods, which represent the most widely used form of analysis in the biopharmaceutical industry.MethodsWe have conducted a comprehensive survey of purity methods, and show that all performance characteristics fall within narrow measurement ranges. This observation was used to develop a model called Uncertainty Based on Current Information (UBCI), which expresses these performance characteristics as a function of the si… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
9
0

Year Published

2012
2012
2025
2025

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 39 publications
0
9
0
Order By: Relevance
“…Hydrophilic interaction chromatography (HILIC) glycan map was performed as previously described. 10 In brief, glycans were released by adding 1 mL of PNGase F to 25 mg of protein and incubating for 2 h at 37 C. The released glycans were labeled with 50 mL solution containing 12 mg/mL 2-aminobenzoic acid, 0.2 M sodium cyanoborohydride, 0.8% (w/v) sodium acetate, and 0.4% (w/v) boric acid. The reaction was allowed to proceed for 75 min at 80 C. After the reaction, the samples were filtered and centrifuged.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Hydrophilic interaction chromatography (HILIC) glycan map was performed as previously described. 10 In brief, glycans were released by adding 1 mL of PNGase F to 25 mg of protein and incubating for 2 h at 37 C. The released glycans were labeled with 50 mL solution containing 12 mg/mL 2-aminobenzoic acid, 0.2 M sodium cyanoborohydride, 0.8% (w/v) sodium acetate, and 0.4% (w/v) boric acid. The reaction was allowed to proceed for 75 min at 80 C. After the reaction, the samples were filtered and centrifuged.…”
Section: Methodsmentioning
confidence: 99%
“…An inadequate number of replicates can result in a significant overestimation or underestimation of method performance. 7,10 The work of Hayashi and Matsuda on function of mutual information theory [11][12][13][14][15][16] and Apostol et al 10 using Uncertainty Based on Current Information (UBCI) model showed that the precision of chromatographic methods can be predicted. However, owing to complexity and limited demonstration of applicability, these approaches have not been widely practiced.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Typically, method precision is established from replicate analyses of the same sample. However, methods for predicting precision have recently been published that allow the assessment of precision based on a single chromatogram (Apostol, Kelner et al 2012).…”
Section: Precisionmentioning
confidence: 99%
“…Apostol et al (Apostol, Kelner et al 2012) proposed a new approach to assessing the uncertainty of purity analyses that uses a more holistic approach that is called Uncertainty Based on Current Information (UBCI). The model allows for real-time assessment of all performance characteristics using the results of the specific separation of interest.…”
Section: Precisionmentioning
confidence: 99%