2010
DOI: 10.1016/j.crhy.2010.05.001
|View full text |Cite
|
Sign up to set email alerts
|

Uncooled bolometer-type Terahertz focal plane array and camera for real-time imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
59
0
3

Year Published

2012
2012
2023
2023

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 130 publications
(64 citation statements)
references
References 10 publications
2
59
0
3
Order By: Relevance
“…Furthermore, if occlusion is an issue as shown earlier (16), the region of interest may give erroneous data due to the dynamic nature of the sample and the sequential process of acquisition. One option to increase imaging speed is to synchronously acquire multiple pixels at once through the use of an array of emitters and/or detectors and there have been some significant improvements presented recently on the development of efficient microbolometer arrays for detection (44)(45)(46). However, such arrays are not suitable for time-domain imaging as they have limited ability to capture the spectral information available, and arrays of time-domain sources and detectors remain expensive and difficult to fabricate.…”
Section: Imaging Speedmentioning
confidence: 99%
“…Furthermore, if occlusion is an issue as shown earlier (16), the region of interest may give erroneous data due to the dynamic nature of the sample and the sequential process of acquisition. One option to increase imaging speed is to synchronously acquire multiple pixels at once through the use of an array of emitters and/or detectors and there have been some significant improvements presented recently on the development of efficient microbolometer arrays for detection (44)(45)(46). However, such arrays are not suitable for time-domain imaging as they have limited ability to capture the spectral information available, and arrays of time-domain sources and detectors remain expensive and difficult to fabricate.…”
Section: Imaging Speedmentioning
confidence: 99%
“…23,24 Currently, most THz imaging applications using THz QCL sources have been demonstrated by exploiting the direct detection using slow THz detectors. [25][26][27] Actually, the ultrafast detection mechanism can be also used for imaging. In 2005, Barbieri et al successfully demonstrated inter-mode beat note imaging with THz QCLs using a fast Schottky diode mixer.…”
Section: © 2017 Author(s) All Article Content Except Where Otherwismentioning
confidence: 99%
“…Two types of THz-FPAs, namely, broad-band type and narrow-band type microbolometer THz-FPAs, have been developed so far [9], [18], [19] and they have 320x240 format and 23.5 μm pixel pitch. Figure 1 shows pixel structures of both broad-band and narrow-band types.…”
Section: Microbolometer Thz Focal Plane Array (Thz-fpa)mentioning
confidence: 99%
“…Microbolometer focal plane arrays (FPAs) have recently been developed specifically for the THz frequency range by several groups [9]- [11] . NEC, the company of the first author of this paper, has begun initial production of a palm-size THz camera which operates at a 30Hz frame rate [12] .…”
Section: Introductionmentioning
confidence: 99%