2019
DOI: 10.1016/j.snb.2019.02.110
|View full text |Cite
|
Sign up to set email alerts
|

Understanding blood oxygenation in a microfluidic meander double side membrane contactor

Abstract: Lung disease is one of the most important causes of high morbidity in preterm infants. In this work, we study a simple and easy to fabricate microfluidic device that demonstrates a great potential for blood oxygenation. A meander type architecture with double side vertical membrane arrangement has been selected as reference model to investigate the oxygenation process. The design criteria for the fabricated devices has been to maximize the oxygen saturation level while ensuring the physiological blood flow in … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
20
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 15 publications
(20 citation statements)
references
References 25 publications
0
20
0
Order By: Relevance
“…A detailed description of the computational fluid dynamics model can be found in our previous work. [ 31 ] The mesh‐size used in the simulations was chosen on the basis of computational costs and reproducibility of hydrodynamic results. On this regard, the 2D computational domain for the reference AD1 design was discretized by more than 160 000 triangular elements, with a mesh of an edge length in the range 3000–16 µm.…”
Section: Numerical and Experimental Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…A detailed description of the computational fluid dynamics model can be found in our previous work. [ 31 ] The mesh‐size used in the simulations was chosen on the basis of computational costs and reproducibility of hydrodynamic results. On this regard, the 2D computational domain for the reference AD1 design was discretized by more than 160 000 triangular elements, with a mesh of an edge length in the range 3000–16 µm.…”
Section: Numerical and Experimental Methodsmentioning
confidence: 99%
“…The PDMS was chosen due to its highly elastic properties, transparency, high gas permeability, biocompatibility, and easiness in releasing from moulds which characterizes a good material for replica moulding. [ 31 ] The fabrication process involved: (1) construction of liquid and gas chambers by replica moulding from rigid masters, (2) membrane fabrication, and (3) microdevice assembly and attachment (see Figures S1 and S2 in the Supporting Information). The detailed fabrication description can be found in.…”
Section: Numerical and Experimental Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…They are considered environmentally friendly and economic because of the simple procedure for their preparation and the very low amount of solvent and extractant used [18,[20][21][22][23][24]. In general, polyvinyl chloride (PVC) and cellulose triacetate (CTA) were used as basic materials [25][26][27][28][29][30]. The removal of chromium(VI) from industrial effluents and contaminated waters is very important because of its high toxicity and impact on both human health and the environment.…”
Section: Introductionmentioning
confidence: 99%
“…The removal of chromium(VI) from industrial effluents and contaminated waters is very important because of its high toxicity and impact on both human health and the environment. Chromium (VI) extraction has been widely investigated using PIM, and the most used devices have been double compartment or microdevices [18,25,31,32]. All systems investigated by researchers have been double cell systems or microsystem channels.…”
Section: Introductionmentioning
confidence: 99%