2022
DOI: 10.3390/ijtpp7030023
|View full text |Cite
|
Sign up to set email alerts
|

Unsteady Analysis of a Pulsating Alternate Flow Pattern in a Radial Vaned Diffuser

Abstract: In centrifugal compressors, Mild Surge (MS) leads to unstable operation. Previous experimental work on a centrifugal compressor designed and built by Safran Helicopter Engines (SafranHE) showed that MS corresponds to the pulsation of an alternate stall pattern at the Helmholtz frequency of the test rig on two channels in the radial diffuser. The present contribution experimentally investigates the impact of the Inlet Guide Vane (IGV) stagger angle on this alternate flow and numerically studies the topology of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…Pressure and temperature are measured with 130 steady sensors to derive performance. Unsteady pressure measurements are also carried out using 52 case-mounted Kulite transducers to investigate aerodynamic phenomena, see (Moënne-Loccoz et al, 2020;Poujol et al, 2022) for details. Regarding some specifics, the overall stage total-to-static pressure ratio is around 4, and the Mach number at the exit of the impeller is about 1.2 at the rotational speed of interest derived from the peripheral velocity.…”
Section: Methodology Experimental Setupmentioning
confidence: 99%
See 2 more Smart Citations
“…Pressure and temperature are measured with 130 steady sensors to derive performance. Unsteady pressure measurements are also carried out using 52 case-mounted Kulite transducers to investigate aerodynamic phenomena, see (Moënne-Loccoz et al, 2020;Poujol et al, 2022) for details. Regarding some specifics, the overall stage total-to-static pressure ratio is around 4, and the Mach number at the exit of the impeller is about 1.2 at the rotational speed of interest derived from the peripheral velocity.…”
Section: Methodology Experimental Setupmentioning
confidence: 99%
“…Experimental observations of the alternate flow pattern are based on an alternate rate derived by projecting all sensors in a single or two passages. Spectral analysis of pressure fluctuations reveals the lock-in phenomenon which may occur between the alternate pattern and the Helmholtz frequency of the test facility (Poujol et al, 2022). When the compressor is operated in mild surge, this pattern phase-locks with the associated planar pressure wave.…”
Section: Introductionmentioning
confidence: 94%
See 1 more Smart Citation