2014
DOI: 10.1039/c4cp01176g
|View full text |Cite
|
Sign up to set email alerts
|

Unusually high fluorescence quantum yield of a homopolyfluorenylazomethine – towards a universal fluorophore

Abstract: The absolute fluorescence quantum yield (Φfl) of a polyfluorenyl azomethine homopolymer was measured as a function of solvent polarity. The solvent induced and temperature dependent fluorescence of the homopolymer were also investigated and they were compared to the corresponding monomer and copolymer. The Φfl of the homopolymer was consistent (45-70%), regardless of solvent polarity with Stokes shifts up to 7460 cm(-1) in ethanol. In contrast, the Φfl of its corresponding monomer decreased from 60% in ethanol… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(15 citation statements)
references
References 70 publications
0
15
0
Order By: Relevance
“…Low temperature PL spectra were obtained using 5 mM metal complex in an ethanol : methanol (4 : 1) mixture that was cooled to 85 K using an OptistatDN Variable Temperature Liquid Nitrogen Cryostat equipped with custom-made quartz sample holder. 54 The temperature of 85 K was used to avoid damage to the spectroscopic cuvettes which occurred at 77 K. 55 We previously found no signicant difference in l max in the spectra of [Ru(bpy) 3 ] 2+ and Ir(ppy) 3 measured at these two temperatures under these instrumental conditions. 54 All PL emission spectra were corrected for the change in instrumental sensitivity over the wavelength range by multiplication with correction curves established using a quartz halogen tungsten lamp.…”
Section: Synthesismentioning
confidence: 97%
“…Low temperature PL spectra were obtained using 5 mM metal complex in an ethanol : methanol (4 : 1) mixture that was cooled to 85 K using an OptistatDN Variable Temperature Liquid Nitrogen Cryostat equipped with custom-made quartz sample holder. 54 The temperature of 85 K was used to avoid damage to the spectroscopic cuvettes which occurred at 77 K. 55 We previously found no signicant difference in l max in the spectra of [Ru(bpy) 3 ] 2+ and Ir(ppy) 3 measured at these two temperatures under these instrumental conditions. 54 All PL emission spectra were corrected for the change in instrumental sensitivity over the wavelength range by multiplication with correction curves established using a quartz halogen tungsten lamp.…”
Section: Synthesismentioning
confidence: 97%
“…It is possible that the defect-free NP surface obtained during consecutive forward and reverse phase transfer is responsible for such exceptional optical properties [ 16 ]. This value of PL QY is e.g., much higher than for most of the blue emitting organic fluorophores [ 17 ].…”
Section: Resultsmentioning
confidence: 99%
“…For the low temperature emission spectra, the complexes were prepared at 5 μM in ethanol : methanol (4 : 1) and cooled to 85 K using an OptistatDN Variable Temperature Liquid Nitrogen Cryostat equipped with custom-made quartz sample holder. The low temperature spectra were collected at 85 K to avoid damage to the spectroscopic cuvettes near 77 K observed during our previous study17 and by others 57. No significant difference in the λ max for metal complexes such as [Ru(bpy) 3 ] 2+ and Ir(ppy) 3 between 77 K and 85 K was observed under these instrumental conditions 30.…”
Section: Methodsmentioning
confidence: 94%