2017
DOI: 10.1016/j.knee.2017.05.001
|View full text |Cite
|
Sign up to set email alerts
|

Up to 10 year follow-up of the Oxford Domed Lateral Partial Knee Replacement from an independent centre

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
21
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(25 citation statements)
references
References 22 publications
3
21
0
1
Order By: Relevance
“…These results were obtained by the designer surgeons, and may limit the generalisability of the results. However, other centres have reported similar results with similar dislocation rates 14,[25][26][27] . It is a single centre, single arm series with no comparator groups.…”
Section: Discussionsupporting
confidence: 66%
See 1 more Smart Citation
“…These results were obtained by the designer surgeons, and may limit the generalisability of the results. However, other centres have reported similar results with similar dislocation rates 14,[25][26][27] . It is a single centre, single arm series with no comparator groups.…”
Section: Discussionsupporting
confidence: 66%
“…Despite the increased entrapment of the biconcave bearing decreasing the dislocation rate, at 4% in the designer's series, it is still unacceptably high. Other independent series report dislocation rates of 2%, 2%, 4% and 6% 14,[25][26][27] . The Fixed bearing Lateral Oxford (FLO; Zimmer Biomet, Warsaw, United States of America) tibial component was introduced, in part, to address this problem.…”
Section: Discussionmentioning
confidence: 92%
“…The Lateral Domed Oxford UKR's bearing dislocation rate in our study was 2.3%, which is similar to other studies in the literature which report rates generally between 1.5-6% [12][13][14][15][16][17].…”
Section: Discussionsupporting
confidence: 90%
“…The introduction of this implant and improvements in the surgical technique reduced the rate of bearing dislocation to 1.7%, in the first report from the designer surgeons [12]. However subsequent reports from the designers and other centres have reported variable dislocation rates between 1.5% and 6%, with many being the result of trauma [13][14][15][16][17].…”
Section: Introductionmentioning
confidence: 99%
“…The optimal design for medial UKA continues to be debated [33,34], and probably the surgeon should choose the implant design that he/she is familiar with for bi-UKA. Especially, the reports of outcome after mobile-bearing lateral UKA have been diverse [35][36][37]. Pandit et al used the Oxford Domed Lateral for staged bi-UKA and reported that there were no significant surgery-related complications and that there was no need for any further surgical procedures or revisions [19].…”
Section: Implant Selectionmentioning
confidence: 99%