2007
DOI: 10.1080/00140130701674331
|View full text |Cite
|
Sign up to set email alerts
|

Updating reference values and predictive models of the OCRA method in the risk assessment of work-related musculoskeletal disorders of the upper limbs

Abstract: A database has been established combining existing data for 23 groups of workers with different level of exposure to repetitive movements of the upper limbs. For all groups, data were available regarding an exposure index (OCcupational Repetitive Actions - OCRA index) and clinically determined UL-WMSDs outcomes (PA = Prevalence of workers affected by one or more UL-WMSDs; PC = Prevalence of single diagnosed cases of an UL-WMSDs). Using these data, new critical values of the OCRA index have been estimated for d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
25
0
4

Year Published

2009
2009
2023
2023

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 68 publications
(31 citation statements)
references
References 8 publications
0
25
0
4
Order By: Relevance
“…OCRA has shown moderate correspondence with ACGIH HAL and the strain index (63,96). Prevalence of upper-limb disorders has been greater in jobs with a higher, as opposed to lower OCRA index (97,98). No studies on the repeatability of the method were found.…”
Section: Occupational Repetitive Actions (Ocra)mentioning
confidence: 99%
“…OCRA has shown moderate correspondence with ACGIH HAL and the strain index (63,96). Prevalence of upper-limb disorders has been greater in jobs with a higher, as opposed to lower OCRA index (97,98). No studies on the repeatability of the method were found.…”
Section: Occupational Repetitive Actions (Ocra)mentioning
confidence: 99%
“…Therefore, at many other assembly productions ergonomic risks at workplaces are much higher. For example, Occhipinti and Colombini (2007) studied 22 categories of workplaces from different industries, including oven assembly, refrigerator assembly, electric motors assembly and upholstering of car seats. They found the average level of ergonomic risks to exceed the acceptable level recommended by European norms in all the studied assemblies.…”
Section: Insights For Generation Of Artificial Data-sets In Comparisomentioning
confidence: 99%
“…Some of the tools already developed are, for instance, OWAS (Karhu et al 1977) (and the associated software WinOWAS (Tiilikainen, 1996)), RULA (McAtamney & Corlett, 1993), Strain Index (Moore and Garg 1995), NIOSH (Waters et al 1993), (NIOSH, 1994), OCRA (Occhipinti, 1998), (Occhipinti & Colombini 2007), Quick Exposure Check (Li & Buckle, 1999), a fuzzy predictive model developed by McCauley Bell (McCauley-Bell & Badiru, 1996a) and FAST ERGO_X (Nunes, 2009a). The two systems developed by the chapter authors will be presented below.…”
Section: Ergonomic Tools For Assessing Wmsd Risk Factorsmentioning
confidence: 99%