2011
DOI: 10.1016/j.atmosenv.2011.06.069
|View full text |Cite
|
Sign up to set email alerts
|

Uptake rate behavior of tube-type passive samplers for volatile organic compounds under controlled atmospheric conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
10
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(11 citation statements)
references
References 44 publications
1
10
0
Order By: Relevance
“…Thus, the 7-day passive sampling efficiency can be calculated using the following empirical equation: Then the UR eff is calculated for a VOC by Equation (2). Equation (11) suggests that more volatile chemicals will have large loss during long-term passive sampling, which agreed with the literature [28,40,45].…”
Section: Effective Uptake Rates For Long-term Environmental Samplingsupporting
confidence: 79%
See 2 more Smart Citations
“…Thus, the 7-day passive sampling efficiency can be calculated using the following empirical equation: Then the UR eff is calculated for a VOC by Equation (2). Equation (11) suggests that more volatile chemicals will have large loss during long-term passive sampling, which agreed with the literature [28,40,45].…”
Section: Effective Uptake Rates For Long-term Environmental Samplingsupporting
confidence: 79%
“…They also bypassed complex calculations involving other physicochemical properties, chemical-adsorbent interaction and adsorption isotherm. For example, terpenes, aromatics, acetates and alkanes displayed different UR change patterns with respect to exposure time [40]. The efficiency of passive samplers is strongly influenced by adsorption isotherms, such as Langmuir, Freundlich and Dubinin-Radushkevich isotherms [48].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The ranking of sites according to VOC concentration corresponds well with the traffic volume, and other anthropogenic activities at respective sites. The values of BTEX at all the categories were lower than the values reported by Meena et al The lower values may be because of the diffusion based passive sampling methodology used for the adsorption of gases [42] [43]. However these values can be used for dose based study on human health (Epidemiological studies) [44].…”
Section: Residential Corridormentioning
confidence: 71%
“…2011a and2011b;Gonzalez-Flesca and Frezier, 2005;Yılmaz Civan et.al. 2012;ASTM D 6196-03;Kumar and Viden, 2007) so it is necessary to experimentally determine uptake rates under application relevant conditions.…”
Section: Introductionmentioning
confidence: 99%