2016
DOI: 10.15406/jdvar.2016.04.00113
|View full text |Cite
|
Sign up to set email alerts
|

Use of AliveCor Heart Monitor for Heart Rate and Rhythm Evaluation in Dairy Water Buffalo Calves (Bubalis Bubalis)

Abstract: Smartphone-based ECG recording devices are a promising new diagnostic in veterinary medicine. However, these devices have not yet been demonstrated to work in water buffalo. A commercial, non-invasive, smartphone-based ECG (AliveCor Vet TM) monitoring device was field tested on water buffalo calves. Six neonatal water buffalo calves had an ECG simultaneously recorded with a standard medical ECG recorder and the AliveCor Vet device. A correlation of 0.75053 was observed between average heart rates obtained betw… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
18
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(20 citation statements)
references
References 13 publications
2
18
0
Order By: Relevance
“…Heart rate was measured manually from printed ECGs for both standard and smartphone ECGs (BA and ST); heart rate as automatically calculated via the smartphone app was also recorded. Complex measurements (amplitudes and durations of all waveforms and intervals) and assessment of cardiac rhythm were performed on standard and smartphone BA ECGs as previously reported (7,8). Additionally, all ECGs were quality scored based on the presence or absence of baseline undulation and tremor artifacts using a three point scoring system (lowest possible = 0; highest possible = 3) previously described for veterinary use (8,9).…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…Heart rate was measured manually from printed ECGs for both standard and smartphone ECGs (BA and ST); heart rate as automatically calculated via the smartphone app was also recorded. Complex measurements (amplitudes and durations of all waveforms and intervals) and assessment of cardiac rhythm were performed on standard and smartphone BA ECGs as previously reported (7,8). Additionally, all ECGs were quality scored based on the presence or absence of baseline undulation and tremor artifacts using a three point scoring system (lowest possible = 0; highest possible = 3) previously described for veterinary use (8,9).…”
Section: Discussionmentioning
confidence: 99%
“…This technique has been described for dairy cattle ( 7 ) as well as dogs ( 13 ). Practitioners should be aware that other techniques for improving skin contact have been described, such as the use of ultrasound gel or clipping of the skin ( 3 , 8 ). It is currently unknown what effect, if any these methods of improving contact have on ECG quality.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations