Use of an Over-the-Scope Clip for Closure of an Iatrogenic Nephrocolic Fistula Resulting From Cryoablative Therapy for Renal Cell Cancer of a Transplanted Renal Graft
Abstract:Although uncommon, cryoablation of tumors can result in collateral damage to adjacent organs resulting in difficult-to-treat perforation and fistulization. Full-thickness closure of defects has been described with the use of over-the-scope clips. We describe the case of a 56-year-old woman who underwent cryoablation of renal cell carcinoma of her transplanted kidney that was complicated by cryoinjury to her sigmoid colon with subsequent nephrocolic fistula and abscess formation resistant to conservative treatm… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.