Bioluminescence - Recent Advances in Oceanic Measurements and Laboratory Applications 2012
DOI: 10.5772/37055
|View full text |Cite
|
Sign up to set email alerts
|

Use of ATP Bioluminescence for Rapid Detection and Enumeration of Contaminants: The Milliflex Rapid Microbiology Detection and Enumeration System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
21
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(21 citation statements)
references
References 48 publications
0
21
0
Order By: Relevance
“…In the ATP bioluminescence method (ATP-B), the bioluminescence mechanism involves the enzyme luciferase in the presence of luciferin, oxygen (O 2 ), magnesium and ATP. This reaction leads to the emission of photons and the intensity of the light produced is directly proportional to the rate of ATP [ 117 ]. However, this method is not applicable to the genus Aspergillus , and to creams or suspensions, since these latest could interfere with the detection of light emission [ 116 ].…”
Section: Preservation Strategiesmentioning
confidence: 99%
“…In the ATP bioluminescence method (ATP-B), the bioluminescence mechanism involves the enzyme luciferase in the presence of luciferin, oxygen (O 2 ), magnesium and ATP. This reaction leads to the emission of photons and the intensity of the light produced is directly proportional to the rate of ATP [ 117 ]. However, this method is not applicable to the genus Aspergillus , and to creams or suspensions, since these latest could interfere with the detection of light emission [ 116 ].…”
Section: Preservation Strategiesmentioning
confidence: 99%
“…The best example is the ATP bioluminescence assay, which is based on the use of an ATP marker to detect presence of bacteria. The reaction assay is based on the D-luciferin oxidation by the luciferase, where the emitted light from the bioluminescent reaction is proportional to the ATP concentration [ 12 , 13 ]. This method is considered one of the most sensible and rapid (NRT) for microbial detection; its only downside is the need for expensive reagents.…”
Section: Introductionmentioning
confidence: 99%
“…Bioluminescent detection systems, used for in vivo and in vitro analytical methods, have been in the spotlight of research in the past decades (Jiang et al 2018;Xu et al 2016;Sadikot and Timothy 2005;Chollet and Ribault 2012;Sato et al 2004). The advantage of these systems over fluorescent systems lies in their superior sensitivity and easy handling (De Saint-Hubert et al 2012;Hu et al 2012).…”
Section: Introductionmentioning
confidence: 99%