2019
DOI: 10.1007/s10633-019-09715-5
|View full text |Cite
|
Sign up to set email alerts
|

Use of diffusing filters for artificially reducing visual acuity when testing equipment and procedures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 31 publications
2
3
0
Order By: Relevance
“…Lehsing et al 87 also used the 0.1 Bangerter occlusion filter but were only able to achieve 0.40 LogMAR visual acuity. This discrepancy between the expected level and the actual level of visual impairment induced with a 0.1 Bangerter filter is consistent with the findings of Heinrich and Strubin, 104 who concluded that the Bangerter nominal grade did not match the actual effect on visual acuity. To achieve a particular level of visual impairment, other researchers used plus lenses, progressively adding power until the desired level of visual impairment was achieved.…”
Section: Variabilit Y In Expec Ted and Ac Tual Levels Of Simul Ation ...supporting
confidence: 87%
“…Lehsing et al 87 also used the 0.1 Bangerter occlusion filter but were only able to achieve 0.40 LogMAR visual acuity. This discrepancy between the expected level and the actual level of visual impairment induced with a 0.1 Bangerter filter is consistent with the findings of Heinrich and Strubin, 104 who concluded that the Bangerter nominal grade did not match the actual effect on visual acuity. To achieve a particular level of visual impairment, other researchers used plus lenses, progressively adding power until the desired level of visual impairment was achieved.…”
Section: Variabilit Y In Expec Ted and Ac Tual Levels Of Simul Ation ...supporting
confidence: 87%
“…For degraded vision, we did not obtain behavioral acuity estimates in the present study as the focus of the study was a comparison between VEP-based estimates. However, we know from a previous study [ 40 ] that the filter used for degradation typically reduces acuity to a logMAR value of about 1.0, which is matched quite well by the acuity estimates obtained with the heuristic algorithm.…”
Section: Discussionsupporting
confidence: 74%
“…With this eye, VEP-based acuity estimates were obtained either with normal vision or with vision degraded by placing a diffusing filter (1° Light Shaping Diffuser, Luminit, Torrance, CA, USA) in a trial frame in front of the study eye. This filter produced Gaussian blur and reduced acuity to around 0.09 decimal acuity (logMAR = 1.06) as measured behaviorally in a recent study [ 40 ].…”
Section: Methodsmentioning
confidence: 99%
“…The second experiment was performed with six healthy volunteers, aged between 20 and 43 years (mean 28.9 ± 8.7 SD), recruited from the staff of the Center for Ophthalmology at the University of Tuebingen (one volunteer also took part in the first study), according to the same criteria as for the first experiment. Visual acuities were determined using the Freiburg Visual Acuity & Contrast Test (FrACT) [ 10 , 11 ] for BCVA and two artificially reduced viewing conditions using Bangerter occlusion foils (0.6, 0.4) [ 12 ]. In both experiments, only one eye of each participant was assessed.…”
Section: Methodsmentioning
confidence: 99%