Use of Disposable Punch Biopsy Device to Add Foley Catheter Fenestration to Improve Drainage of Post Radical Prostatectomy Anastomotic Leak

Abstract: CONTEXT CONTEXT Radical prostatectomy (RP) is a major oncologic urological surgery that can have high morbidity if complications arise. Bladder-urethral urine anastomotic leaks (AL) are one of the most common complications and can greatly increase morbidity. To date, there are few resources to manage AL. One management technique is using a Foley catheter with an additional auxiliary drainage port, also known as a fenestrated catheter. This type of auxiliary drainage port allows a low-pressure drainage source t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 16 publications
0
2
0
Order By: Relevance
“…The suggestion to improve drainage through multiple holes on a catheter was first proposed by Thurner-Warwick in 1973 [28]. This concept was developed further by others in the postradical prostatectomy setting or after urethral surgery [29,30]. However, to the authors' knowledge, attempting to ensure complete emptying of the bladder and the prevention of J o u r n a l P r e -p r o o f CAUTI have not been investigated previously; noticeably, the balloon itself has never been modified in any of the mentioned self-retaining catheters.…”
Section: Near Here> <A>discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The suggestion to improve drainage through multiple holes on a catheter was first proposed by Thurner-Warwick in 1973 [28]. This concept was developed further by others in the postradical prostatectomy setting or after urethral surgery [29,30]. However, to the authors' knowledge, attempting to ensure complete emptying of the bladder and the prevention of J o u r n a l P r e -p r o o f CAUTI have not been investigated previously; noticeably, the balloon itself has never been modified in any of the mentioned self-retaining catheters.…”
Section: Near Here> <A>discussionmentioning
confidence: 99%
“…This condition typically occurs in FCs, where the bladder is never completely emptied and the flow is intermittent. This situation increases the possibility for bacterial cells to adhere to the surface material and form a biofilm [6,16,[27][28][29][30]. One of the most important criticisms of the FC is that bladder voiding is not complete as the two drainage holes are placed above the balloon, meaning that a certain amount of urine constantly remains around the balloon itself.…”
Section: <A>introductionmentioning
confidence: 99%