2021
DOI: 10.1021/acsfoodscitech.1c00230
|View full text |Cite
|
Sign up to set email alerts
|

Use of Electro-Activated Whey as Ingredient in Fermented Milk Production: Proof of the Concept of the Technological Feasibility

Abstract: Alkaline electro-activation of whey was previously reported to convert 25–45% of lactose into lactulose. Neutralization after electro-activation did not cause the loss of the lactulose yield. Lactulose is an established prebiotic and is used as an additive in fermented dairy products. The aim of this work was to study the behavior of electro-activated whey used as an ingredient in a fermented milk. To carry out this study, prior to fermentation, milk (0, 1, 2, and 3% fat) was supplemented with 3, 6, and 9% ele… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(11 citation statements)
references
References 48 publications
0
11
0
Order By: Relevance
“…The electro-activated whey was prepared as follows: a 10% whey solution (w/w) was electro-activated in the cathodic side of an electro-activation reactor containing three compartments: anodic, cathodic, and central. The used electro-activation rector is made of a Plexiglas material and the central compartment is separated from the anodic and cathodic sides by anion and cation exchange membranes, respectively [ 7 ]. The central compartment was separated from the anodic and cathodic sides by anion and cation exchange membrane, respectively.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The electro-activated whey was prepared as follows: a 10% whey solution (w/w) was electro-activated in the cathodic side of an electro-activation reactor containing three compartments: anodic, cathodic, and central. The used electro-activation rector is made of a Plexiglas material and the central compartment is separated from the anodic and cathodic sides by anion and cation exchange membranes, respectively [ 7 ]. The central compartment was separated from the anodic and cathodic sides by anion and cation exchange membrane, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…The whey solution was introduced in the cathodic compartment where reducing alkaline conditions were created while the other two compartments were filled with 0.1 M and 0.25 M K 2 SO 4 solutions to serve as electrolytes, respectively . After 60 min of electro-activation under a direct electric field of 800 mA, the electro-activated whey solution was kept for relaxation during 48 h at 22 ± 1 °C and then its pH was adjusted to 7 and freeze dried for further use [ 7 ]. Prior to use for bacterial growth, all the selected aqueous solutions of the growth media were filtered through sterile 0.45 μm and 0.2 μm filters.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Various authors have used the different forms of whey to improve the overall processing and product characteristics of whey-based kefir. 17,82,84,85 Magalhaẽs et al used both cheese whey and deproteinized cheese whey as a base material and reported no significant difference between the end acetic acid, ethanol, and lactic acid content of the whey-based kefirs compared to milk based. 10,17 However, there were slight alterations in some volatile components like 2methyl-1-butanol, 1-propanol, but they all were under the threshold values.…”
Section: Kefir Preparationmentioning
confidence: 99%
“…92,93 Aidarbekova et al reported up to 40% conversion of lactose to lactulose using this method. 85 Lactulose is a prebiotic with high solubility and interesting technofunctionality. 92 Fermented dairy products supplemented with lactulose are beneficial in the treatment of constipation.…”
Section: Kefir Preparationmentioning
confidence: 99%