“…Alternative endovascular options include straight tube endografts, 10,15 minimally invasive techniques 9,12,13 or suprarenal complex endografting such as fenestrated endografts or chimney techniques.…”
Section: Discussionmentioning
confidence: 99%
“…The use of endurant aortic extensions in focal abdominal aortic lesions with adequate distal neck confirmed to be safe in a recent publication. 15 Postimplantation ballooning and subsequent aortic rupture required distal extension of endovascular exclusion. In patients at high risk of aortic rupture, we usually performed aortic ballooning according to usual several cares as lowering systemic blood pressure, the use of a compliant balloon with lowpressure inflation, and the use of a long and large sheath to support aortic ballooning held manually to avoid displacement, avoiding expansion of the balloon outside the covered part of the endograft, sometimes with the distal part of the balloon inside the sheath to avoid distal excessive inflation.…”
In hostile proximal abdominal aortic neck, challenging anatomies, or urgent cases, the structural adaptability of thoracic endografts could provide safe and successful abdominal aortic endovascular exclusion.
“…Alternative endovascular options include straight tube endografts, 10,15 minimally invasive techniques 9,12,13 or suprarenal complex endografting such as fenestrated endografts or chimney techniques.…”
Section: Discussionmentioning
confidence: 99%
“…The use of endurant aortic extensions in focal abdominal aortic lesions with adequate distal neck confirmed to be safe in a recent publication. 15 Postimplantation ballooning and subsequent aortic rupture required distal extension of endovascular exclusion. In patients at high risk of aortic rupture, we usually performed aortic ballooning according to usual several cares as lowering systemic blood pressure, the use of a compliant balloon with lowpressure inflation, and the use of a long and large sheath to support aortic ballooning held manually to avoid displacement, avoiding expansion of the balloon outside the covered part of the endograft, sometimes with the distal part of the balloon inside the sheath to avoid distal excessive inflation.…”
In hostile proximal abdominal aortic neck, challenging anatomies, or urgent cases, the structural adaptability of thoracic endografts could provide safe and successful abdominal aortic endovascular exclusion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.