2015
DOI: 10.1007/978-3-319-19387-8_109
|View full text |Cite
|
Sign up to set email alerts
|

Use of flattening filter free photon beams for off-axis targets in conformal arc stereotactic body radiation therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 17 publications
0
8
0
Order By: Relevance
“…16,18 The disadvantage of OAG plans is that they require longer treatment delivery times compared to CAG FFF plans, related to the off-axis distance of the PTV. 16 A further potential concern of OAG is the magnification of misalignment errors in the collimator or couch rotations at the off-axis position. However, these potential errors (<0.5°at the isocenter) were not found to have a clinically significant effect on dose distributions for OAG conventional (flattened) or FFF plans.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations
“…16,18 The disadvantage of OAG plans is that they require longer treatment delivery times compared to CAG FFF plans, related to the off-axis distance of the PTV. 16 A further potential concern of OAG is the magnification of misalignment errors in the collimator or couch rotations at the off-axis position. However, these potential errors (<0.5°at the isocenter) were not found to have a clinically significant effect on dose distributions for OAG conventional (flattened) or FFF plans.…”
Section: Introductionmentioning
confidence: 99%
“…However, these potential errors (<0.5°at the isocenter) were not found to have a clinically significant effect on dose distributions for OAG conventional (flattened) or FFF plans. 16 To verify the dosimetric and geometric accuracy of SABR treatment deliveries, patient-specific quality assurance (QA) is required. A number of two-dimensional (2D)/three-dimensional (3D) dose measurement systems are commercially available and have been commissioned for such work; these typically comprise film, ionization chamber arrays, or semiconductor diode arrays.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Similar to the recent use of modified DCAT to liver SBRT [ 31 ] either with or without flattening-filter-free beams [ 32 ], DrMAT is also easily applicable to other abdominal cancers that are particularly associated with respiratory tumor motion such as liver and pancreas cancers.…”
Section: Discussionmentioning
confidence: 99%