2009
DOI: 10.1007/s00216-009-3346-z
|View full text |Cite
|
Sign up to set email alerts
|

Use of pJANUS™-02-001 as a calibrator plasmid for Roundup Ready soybean event GTS-40-3-2 detection: an interlaboratory trial assessment

Abstract: Owing to the labelling requirements of food and feed products containing materials derived from genetically modified organisms, quantitative detection methods have to be developed for this purpose, including the necessary certified reference materials and calibrator standards. To date, for most genetically modified organisms authorized in the European Union, certified reference materials derived from seed powders are being developed. Here, an assessment has been made on the feasibility of using plasmid DNA as … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
11
0

Year Published

2010
2010
2018
2018

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(11 citation statements)
references
References 19 publications
0
11
0
Order By: Relevance
“…Moreover, three parameters were evaluated to check that the PCR amplification kinetics in the sample extract was not significantly different from those of the calibrant. Previous publications [8,12,29] have already addressed some of these issues, also regarding the variations of the between-laboratory performance. However, they were limited to one specific GM event.…”
Section: Discussionmentioning
confidence: 97%
See 1 more Smart Citation
“…Moreover, three parameters were evaluated to check that the PCR amplification kinetics in the sample extract was not significantly different from those of the calibrant. Previous publications [8,12,29] have already addressed some of these issues, also regarding the variations of the between-laboratory performance. However, they were limited to one specific GM event.…”
Section: Discussionmentioning
confidence: 97%
“…The use of plasmids which contain cloned junctionspecific and endogenous sequences-so-called dual-target plasmids-as calibrants for GM quantification has been demonstrated previously [3][4][5][6][7][8][9][10][11]. However, the validity of the conclusions drawn from these studies is limited, as they have been based on repeatability studies within the same laboratory.…”
Section: Introductionmentioning
confidence: 95%
“…Quantification based in the direct comparison of results obtained from processed samples and those from CRMs should be taken with care, because matrix effects and the loss of integrity of the DNA molecules during processing could bias the estimation of the actual GMO content of the samples. Novel synthetic DNA standards, including genomic and plasmidic DNA molecules that contain the event-specific and reference sequences of interest, have been also proposed as calibrators in real-time PCR methods for GMO quantification [95][96][97][98][99] .…”
Section: Quantification Of Gmos In Foodmentioning
confidence: 99%
“…pDNA calibrators have some advantages compared to gDNA: they are easier to construct; can be produced at lower cost; they are stable frozen or lyophilized and can be stored for a long period of time; they are well-defined and have a fully characterized sequence (Burns et al, 2006;Caprioara-Buda et al, 2012;Wang et al, 2011). Plasmid calibrators have been considered adequate CRM because of their convenience and lower cost (Lievens et al, 2010;Meng et al, 2012).…”
Section: Introductionmentioning
confidence: 99%