Use of radiation pressure for measurement of high-power laser emission

Abstract: We demonstrate a paradigm in absolute laser radiometry where a laser beam's power can be measured from its radiation pressure. Using an off-the-shelf high-accuracy mass scale, a 530 W Yb-doped fiber laser, and a 92 kW CO(2) laser, we present preliminary results of absolute optical power measurements with inaccuracies of better than 7% to 13%. We find negligible contribution from radiometric (thermal) forces. We also identify this scale's dynamic-force noise floor for a 0.1 Hz modulation frequency as 4 μN/Hz(1/… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
25
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 45 publications
(25 citation statements)
references
References 14 publications
0
25
0
Order By: Relevance
“…The accuracy of the fitting curve can be easily checked instantaneously by comparing the values of height h0 obtained from ratios -a2/(2a3) and -2a1/a2, which should agree. From Table 1 we see that for accurate determination of fitting polynomial coefficients it is desirable that the measurement interval covers a range where the second and third derivatives of the function (11) are pronounced. Because this algorithm depends on coefficients of high order polynomial derivatives, it is vulnerable to the presence of noise in the data.…”
Section: Static Characterizationmentioning
confidence: 99%
See 1 more Smart Citation
“…The accuracy of the fitting curve can be easily checked instantaneously by comparing the values of height h0 obtained from ratios -a2/(2a3) and -2a1/a2, which should agree. From Table 1 we see that for accurate determination of fitting polynomial coefficients it is desirable that the measurement interval covers a range where the second and third derivatives of the function (11) are pronounced. Because this algorithm depends on coefficients of high order polynomial derivatives, it is vulnerable to the presence of noise in the data.…”
Section: Static Characterizationmentioning
confidence: 99%
“…The portable laser power meter employing a commercially available force scale for radiation pressure measurements was first introduced by P. Williams, et al [11]. This power meter brought about a considerable shift in how laser power measurement is approached.…”
Section: Introductionmentioning
confidence: 99%
“…This results in traceability through the kilogram, the meter, and the second [20]. Heat balance calorimeter [17] 1.6 % Primary 1 kW -50 kW** [18,19] 1070 Radiation pressure power meter (RPPM)…”
Section: Introductionmentioning
confidence: 99%
“…The connection between force and power can be used to build metrological tools that measure optical power from a known force, or that measure force from a known optical power. In the kilowatt range, radiation pressure has been measured with percent level uncertainties using a calibrated force transducer [2,3]. In the milliwatt range, piconewton forces have been measured with percent level uncertainty using a calibrated optical power [4,5].…”
Section: Introductionmentioning
confidence: 99%