2014 67th Annual Conference for Protective Relay Engineers 2014
DOI: 10.1109/cpre.2014.6798992
|View full text |Cite
|
Sign up to set email alerts
|

Use of synchrophasor measurements in protective relaying applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
7
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(7 citation statements)
references
References 28 publications
0
7
0
Order By: Relevance
“…PMU based time-synchronized measurements are also used in relay protection and FL identification. PS Relaying Committee Report of Working Group C-14 presented some of the useful relaying applications which cover power swing detection, line reclosing selectivity, synchrophasor assisted black start, automatic generator shedding, distance protection, bus differential protection and line differential protection [72].…”
Section: Fault Location Identification and Protective Relayingmentioning
confidence: 99%
“…PMU based time-synchronized measurements are also used in relay protection and FL identification. PS Relaying Committee Report of Working Group C-14 presented some of the useful relaying applications which cover power swing detection, line reclosing selectivity, synchrophasor assisted black start, automatic generator shedding, distance protection, bus differential protection and line differential protection [72].…”
Section: Fault Location Identification and Protective Relayingmentioning
confidence: 99%
“…In this context, synchrophasor technology provides suitable tools to improve backup protection for wide area application. A phasor data concentrator (PDC/controller) in one single location can decide if there is a fault in the protected zone and, consequently, avoid unnecessary Zone 3 tripping caused by load encroachment [5]. Wide area monitoring, protection, and control (WAMPAC) systems include situational awareness applications that help system operators to deal with critical operational conditions that may occur in power systems.…”
Section: Introductionmentioning
confidence: 99%
“…A solution to power swing problem is addressed using PMU data in [10]. PMU data is also used in generator black start [10] islanding and anti-islanding conditions with Distributed Energy Resources (DER) [11], to measure transmission relay parameters [12] and in protective relaying applications [13]. A basic PMU can provide a minimum of 30 samples of data per second.…”
Section: Introductionmentioning
confidence: 99%