Use of the anterior chamber maintainer in anterior segment surgery

Abstract: Over a 12 month period, we used the anterior chamber maintainer (ACM) in cataract surgery in 258 patients; ages ranged from 15 to 95 years (mean 73 years). Surgery was performed using general or local anesthesia. The procedures were standard extracapsular cataract extraction (ECCE), mini-nuc ECCE, vectis extraction of the endonucleus, manual phacofragmentation, phacoemulsification, phacotrabeculectomy, repositioning the IOL, and anterior segment revision. We recorded our subjective assessment of the degree of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
24
0
3

Year Published

1999
1999
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 38 publications
(27 citation statements)
references
References 5 publications
0
24
0
3
Order By: Relevance
“…The purpose of this study was to assess the efficacy and safety of the authors modifications5 of Blumenthal’s “Mini-Nuc” technique and to compare its effects on both non-diabetic and diabetic patients.…”
mentioning
confidence: 99%
“…The purpose of this study was to assess the efficacy and safety of the authors modifications5 of Blumenthal’s “Mini-Nuc” technique and to compare its effects on both non-diabetic and diabetic patients.…”
mentioning
confidence: 99%
“…The ACM (the cost is US $ 10) has been used in cataract surgery, either in manual small incision cataract surgery or in phacoemulsification. [3][4][5][6] There is limitation of Simcoe's cannula and vitrector in this procedure. Both Simcoe's cannula and vitrector have relatively small "mouths" so that they create problems in removing bulky and springy fibrin in the AC.…”
Section: Discussionmentioning
confidence: 99%
“…Assim, quando se deseja aliar custos baixos a bons resultados, dispõe-se da técnica "Mini-Nuc" como excelente alternativa (11)(12)(13)(14) , a qual combina os benefícios da média incisão auto-selante com a extração manual extracapsular da catarata, propondo a utilização de um MAC que promove fluxo contínuo de BSS e garante pressão intra-ocular positiva durante toda a operação.…”
Section: Discussionunclassified
“…À luz de nossos achados, concordamos com Chawla et al (14) no sentido de que há um rol de vantagens na utilização de um MAC para hidroexpressão do núcleo cristaliniano, através da média incisão, sem uso de agentes viscoelásticos ou de facoemulsificação, tais sejam:…”
Section: Discussionunclassified