2020
DOI: 10.1016/j.ejvs.2020.08.018
|View full text |Cite
|
Sign up to set email alerts
|

Use of the Ovation Endograft System to Treat Abdominal Aortic Aneurysms With Hostile Anatomy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 5 publications
0
7
0
Order By: Relevance
“…Since 2010, the Ovation Abdominal Stent Graft System (Endologix Inc. Irvine, CA, USA) has offered a new sealing concept, achieved by a network of O rings filled with a polymer, that can treat a great variety of difficult anatomies through a low profile platform. 1 , 2 In the latest version of the stent graft, called Ovation Alto, the conformable O rings with polyethylene glycol (PEG) polymer have been repositioned nearer the top of the endograft, providing a seal just below the renal arteries (optimally 7 mm below the lowest renal artery).…”
Section: Introductionmentioning
confidence: 99%
“…Since 2010, the Ovation Abdominal Stent Graft System (Endologix Inc. Irvine, CA, USA) has offered a new sealing concept, achieved by a network of O rings filled with a polymer, that can treat a great variety of difficult anatomies through a low profile platform. 1 , 2 In the latest version of the stent graft, called Ovation Alto, the conformable O rings with polyethylene glycol (PEG) polymer have been repositioned nearer the top of the endograft, providing a seal just below the renal arteries (optimally 7 mm below the lowest renal artery).…”
Section: Introductionmentioning
confidence: 99%
“…Freedom from aneurysm-related mortality was 99.6% at 1 year and 99.5% at 3 years. In comparison, another study (44) with a median follow-up of 37 months reported a 2% 30-day mortality (not aneurysm related). Overall freedom from re-intervention was 96%.…”
Section: Ovation IXmentioning
confidence: 85%
“…Up to 4 years after the intervention, the Ovation stent graft device has been proved to be a safe choice for patients with both conventional and hostile anatomy who may fall outside the IFUs of other commonly used device platforms, even in patients with conical proximal necks ( 44 ). Thus, the Ovation system seems to be a fair choice for patients with conical aortic necks.…”
Section: Discussionmentioning
confidence: 99%
“…Gregory et al [11] stated that although existing published data on the ALTO device are limited, if more published data show short-to long-term results comparable to those obtained using the Ovation iX [12][13][14][15][16][17][18][19], then the ALTO device can be used more widely. However, whether ALTO devices can be successfully used in patients with more hostile aortic anatomies remains to be seen, considering the satisfac-tory results of Ovation iX use reported by Sirignano et al [17] and Morgan-Bates and Chaudhuri [19]. Short-term results may be identical between Ovation iX and ALTO device use, but a thorough comparison between the two devices would require long-term follow-ups of patients using ALTO devices.…”
Section: Discussionmentioning
confidence: 99%