2005
DOI: 10.1590/s0103-50532005000200008
|View full text |Cite
|
Sign up to set email alerts
|

Use of the same polymer for synthesis and purification of peptides

Abstract: Este trabalho revela uma estratégia biotecnológica incomum mas valiosa e relacionada com o uso de um mesmo polímero (benzidrilamino-resina, BHAR) para fins de síntese e purificação por troca aniônica de peptídeos. Inicialmente, o octapeptídeo DRVYIHPF-NH 2 foi sintetizado em BHAR com 1% e 3% de intercruzamento e contendo 2,5 mmol g -1 de grupos amônio. Devido certamente a uma menor rigidez da sua estrutura polimérica, um maior rendimento na síntese (cerca de 80%) foi obtido com a primeira resina. A seguir, os … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2009
2009
2009
2009

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 23 publications
(32 reference statements)
0
2
0
Order By: Relevance
“…Different fluorescence responses of the materials arw and drw , may be attributed to the cross-linking degree. In resin a the cross-linking degree is higher than in d , which gives a greater rigidity of the structure matrix and prevents expansion of the polymer backbone, discouraging response from the fluorescent material supported on resin a toward metals …”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Different fluorescence responses of the materials arw and drw , may be attributed to the cross-linking degree. In resin a the cross-linking degree is higher than in d , which gives a greater rigidity of the structure matrix and prevents expansion of the polymer backbone, discouraging response from the fluorescent material supported on resin a toward metals …”
Section: Resultsmentioning
confidence: 99%
“…In resin a the cross-linking degree is higher than in d, which gives a greater rigidity of the structure matrix and prevents expansion of the polymer backbone, discouraging response from the fluorescent material supported on resin a toward metals. 31 The best properties as sensor were found in the materials supported on resin a, since the changes in the fluorescence response with the metals studied were greater. In the case of rz supported on d, the inability to discriminate between the two metals (Ni 2+ and Cu 2+ ) suggests that the properties are not the most appropriate.…”
Section: (A-d)(p-t)(w-z)mentioning
confidence: 97%