2011
DOI: 10.1016/j.urology.2010.06.052
|View full text |Cite
|
Sign up to set email alerts
|

Use of the Valveless Trocar System Reduces Carbon Dioxide Absorption During Laparoscopy When Compared With Standard Trocars

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
47
1

Year Published

2015
2015
2022
2022

Publication Types

Select...
6
2
1

Relationship

2
7

Authors

Journals

citations
Cited by 58 publications
(49 citation statements)
references
References 22 publications
1
47
1
Order By: Relevance
“…One of the main advantages of the AirSeal System, in fact, is its ability to minimize fluctuations in intra-abdominal pressure compared with standard trocars (16). Advantages of stable intra-abdominal pressure include minimization of derangements in hemodynamic and pulmonary parameters, such as blood pressure and airway pressures.…”
Section: Discussionmentioning
confidence: 99%
“…One of the main advantages of the AirSeal System, in fact, is its ability to minimize fluctuations in intra-abdominal pressure compared with standard trocars (16). Advantages of stable intra-abdominal pressure include minimization of derangements in hemodynamic and pulmonary parameters, such as blood pressure and airway pressures.…”
Section: Discussionmentioning
confidence: 99%
“…This device might be advantageous for extraperitoneal and retroperitoneal approaches, where pressureloss episodes could lead to a complete collapse of the surgical site 25 . Use of a valveless trocar significantly reduced CO 2 consumption (P <0.01), CO 2 elimination (P <0.05) and absorption (P <0.05) during transperitoneal laparoscopy compared with the standard trocar after 16 minutes of insufflation 24 . In a prospective comparison with a standard Versaport® Plus V2 (United States Surgical Corporation, USA) trocar, only one episode of pressure loss <8 mmHg occurred using the AirSeal® system, but 38 pressureloss episodes were recorded in the Versaport® group (P <0.0001).…”
Section: Key Pointsmentioning
confidence: 96%
“…Herati et al 24 published data regarding the use of a valveless trocar in laparoscopic renal surgery. The AirSeal® (SurgiQuest Inc., USA) trocar works by creating and maintaining a gas pressure barrier in the proximal end of the trocar, enabling a considerably more stable pneumoperitoneum and pneumoextra peritoneum than standard port systems.…”
Section: Key Pointsmentioning
confidence: 99%
“…[15][16] Several studies have evaluated its use in contrast to that of conventional systems, with some finding reduced operative times, improved pressure maintenance, and lower CO2 consumption in favor of the Airseal® system. [16][17] A prospective trial focusing on patients undergoing robot-assisted radical prostatectomy found improved insufflation pressure stability and reduced number of trocar manipulations amongst the Airseal® arm. However, overall surgical time and CO2 consumption did not differ between the groups.…”
Section: Valve-less Trocarmentioning
confidence: 99%