2021
DOI: 10.1177/19714009211021775
|View full text |Cite
|
Sign up to set email alerts
|

Usefulness of black-blood magnetic resonance angiography generated from vessel wall imaging after the stent-assisted treatment of intracranial arterial diseases

Abstract: Purpose After stent-assisted treatment for intracranial diseases, three-dimensional time-of-flight magnetic resonance angiography is a noninvasive follow-up method, but susceptibility artifacts prevent accurate evaluations of stented arteries. Sampling perfection with application-optimized contrast using different flip angle evolution (SPACE) sequence often used for vessel wall imaging is less susceptible to susceptibility artifacts, since it is a spin-echo sequence. Hence, we evaluated the feasibility of blac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 18 publications
0
2
0
Order By: Relevance
“…As 3D-VWI using a variable flip angle is a spin echo-based sequence, it is less affected by the magnetic susceptibility artifact produced by the stent, thrombi in the stent can be visualized, 73 and the diameter of the stented artery can be evaluated more accurately. 74 In addition, by postprocessing via partial minimum intensity projection (MinIP) in the source data of 3D-VWI to create a BB-MRA, it becomes easier to visually evaluate the stent lumen, as can be seen in MIP images of 3D-TOF MRA. 74 …”
Section: Visualization Of the Stented Artery Lumenmentioning
confidence: 99%
See 1 more Smart Citation
“…As 3D-VWI using a variable flip angle is a spin echo-based sequence, it is less affected by the magnetic susceptibility artifact produced by the stent, thrombi in the stent can be visualized, 73 and the diameter of the stented artery can be evaluated more accurately. 74 In addition, by postprocessing via partial minimum intensity projection (MinIP) in the source data of 3D-VWI to create a BB-MRA, it becomes easier to visually evaluate the stent lumen, as can be seen in MIP images of 3D-TOF MRA. 74 …”
Section: Visualization Of the Stented Artery Lumenmentioning
confidence: 99%
“… 74 In addition, by postprocessing via partial minimum intensity projection (MinIP) in the source data of 3D-VWI to create a BB-MRA, it becomes easier to visually evaluate the stent lumen, as can be seen in MIP images of 3D-TOF MRA. 74 …”
Section: Visualization Of the Stented Artery Lumenmentioning
confidence: 99%