Background: Right atrial pressure (RAP) is commonly estimated using inferior vena cava (IVC) diameter and its respirophasic variations. Although a guideline has been provided for estimation of RAP due to variation in IVC dimensions based on studies in Western subjects, echocardiographic values in Asian subjects are unknown.
Methods and Results:We studied 369 patients who underwent IVC ultrasound within 24 h of right heart catheterization (RHC). The maximum and minimum IVC diameter during a respiratory cycle and the percent collapse after a sniff test were measured. These IVC parameters were compared with mean RAP measured on RHC. Receiver operating characteristic curves were generated for each IVC parameter to determine the optimal cut-off to detect RAP >10 mmHg. The IVC maximum diameter cut-off for detecting RAP >10 mmHg was 19 mm (sensitivity, 75%; specificity, 78%) and the percent collapse cut-off was 30% (sensitivity, 75%; specificity, 83%). Both cut-offs were smaller than those previously reported in patients from Western countries. When the cut-off values from the existing guideline were applied to the present cohort, the sensitivity and specificity for normal RAP (0-5 mmHg) were 38.6% and 74.2%, respectively, and 60.0% and 92.0% for elevated RAP (>10 mmHg).
Conclusions:The optimal IVC maximum diameter and percent collapse cut-offs to detect elevated RAP were smaller in Asian subjects than in a previously reported Western cohort. (Circ J 2014; 78: 962 -966)