2018
DOI: 10.1016/j.amjcard.2018.05.044
|View full text |Cite
|
Sign up to set email alerts
|

Usefulness of Transcatheter Aortic Valve Implantation for Treatment of Pure Native Aortic Valve Regurgitation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
53
1
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 57 publications
(57 citation statements)
references
References 14 publications
2
53
1
1
Order By: Relevance
“…Prior studies have demonstrated the higher dose of contrast agents required during TAVR for pure AR (median volume, 150–180 ml/procedure 10,12 ) than TAVR for AS (80–110 ml/procedure 23,24 ). In addition, patients with AR often have a large aortic annulus, which can lead to further difficulty in valve anchoring and increases the risk of valve embolization and migration 11 . In the present study, the higher risk of AKI may also have led to a longer length of stay in TAVR for pure AR due to the need for observation of kidney function.…”
Section: Discussionmentioning
confidence: 71%
See 3 more Smart Citations
“…Prior studies have demonstrated the higher dose of contrast agents required during TAVR for pure AR (median volume, 150–180 ml/procedure 10,12 ) than TAVR for AS (80–110 ml/procedure 23,24 ). In addition, patients with AR often have a large aortic annulus, which can lead to further difficulty in valve anchoring and increases the risk of valve embolization and migration 11 . In the present study, the higher risk of AKI may also have led to a longer length of stay in TAVR for pure AR due to the need for observation of kidney function.…”
Section: Discussionmentioning
confidence: 71%
“…In the present study, the higher risk of AKI may also have led to a longer length of stay in TAVR for pure AR due to the need for observation of kidney function. Importantly, a previous study has demonstrated that patients who developed AKI with TAVR for pure AR had higher mortality at one‐year after TAVR 11 . Other investigators have shown that procedure time is longer in TAVR for pure AR, 10,12,23,24 possibly increasing the risk of procedure‐related bleeding.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The authors found no causal explanation for this phenomenon other than valve design and absence of calcification. [48]…”
Section: Tavi For Npar: Evidence On New Generation Devicesmentioning
confidence: 99%