Using a bio-inspired copper complex to investigate reactive mass transfer around an oxygen bubble rising freely in a thin-gap cell

Abstract: Using a bio-inspired copper complex to investigate reactive mass transfer around an oxygen bubble rising freely in a thin-gap cell.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
33
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 16 publications
(34 citation statements)
references
References 44 publications
1
33
0
Order By: Relevance
“…Previously we used a SuperFocus mixer to investigate the kinetics of fast reactions by continuous flow. [12c], Due to the short mixing time of this setup it was possible to analyze the formation of [Cu 2 O 2 (btmgp) 2 ]I 2 , a temperature sensitive guanidine‐stabilized bis(µ‐oxido) species at room temperature . In contrast, the reaction of 1 with O 2 at room temperature is slower with a faster decay (for decay k obs = 0.06 s –1 at 25 °C, see below).…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Previously we used a SuperFocus mixer to investigate the kinetics of fast reactions by continuous flow. [12c], Due to the short mixing time of this setup it was possible to analyze the formation of [Cu 2 O 2 (btmgp) 2 ]I 2 , a temperature sensitive guanidine‐stabilized bis(µ‐oxido) species at room temperature . In contrast, the reaction of 1 with O 2 at room temperature is slower with a faster decay (for decay k obs = 0.06 s –1 at 25 °C, see below).…”
Section: Resultsmentioning
confidence: 99%
“…While it turned out that 1 is not suitable for the investigation of its reactivity with dioxygen in bubbly flows this is different for an iron peroxido complex reported by some of us previously. [12c], Besides the problems with protic solvents, rates for formation and decay of reactive intermediates need to be in a time window to allow their study in an industrial setup such as a bubble flow column.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Additionally, laser‐induced fluorescence (LIF) measurements of the concentration field around the bubble can be carried out by adding a dye and quenching its fluorescence after contact with gas transferred into the liquid phase 13. Furthermore, tailored chemical reaction systems can be applied, visualizing the local mass transfer by a color changing reaction 16–18. While all of these techniques have their advantages and drawbacks, they are all limited to optically accessible systems and rely on tracers or chemicals, contaminating the investigated system.…”
Section: Introductionmentioning
confidence: 99%