2004
DOI: 10.1016/j.epsr.2004.04.013
|View full text |Cite
|
Sign up to set email alerts
|

Using a FACTS device controlled by a decentralised control law to damp the transient frequency deviation in a deregulated electric power system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
14
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 36 publications
(14 citation statements)
references
References 12 publications
0
14
0
Order By: Relevance
“…A lot of studies have been made about AGC in a restructured power industry over last decades. These studies try to modify the conventional LFC system [30] to take into account the effect of bilateral contracts on the dynamics [12] and improve the dynamical transient response of the system under competitive conditions [9,18,19]. This paper proposes a control scheme that guarantees a minimum transient deviation and ensures zero steady state error.…”
Section: Introductionmentioning
confidence: 98%
“…A lot of studies have been made about AGC in a restructured power industry over last decades. These studies try to modify the conventional LFC system [30] to take into account the effect of bilateral contracts on the dynamics [12] and improve the dynamical transient response of the system under competitive conditions [9,18,19]. This paper proposes a control scheme that guarantees a minimum transient deviation and ensures zero steady state error.…”
Section: Introductionmentioning
confidence: 98%
“…An auxiliary stabilizing signal can also be superimposed on the power flow control function of the SSSC so as to improve power system oscillation stability [4]. The applications of SSSC for power oscillation damping, stability enhancement and frequency stabilization can be found in several references [5][6][7][8].…”
Section: Introductionmentioning
confidence: 99%
“…SSSC is one of the FACTS devices, which connected in series with transmission line [5]. During the past decades, in order to improve LFC performance of interconnected power system, installing SSSC between areas has been used [3,[5][6]. Parameters of the lead-lag controller have been optimized by a micro-genetics algorithm using evaluation of the fitness function which is based on a linear combination of damping ratio of the inter-area mode and the multiplicative stability margin for taking system uncertainties into account [4].…”
Section: Introductionmentioning
confidence: 99%