2010
DOI: 10.1002/rcm.4431
|View full text |Cite
|
Sign up to set email alerts
|

Using an ultrapure 4He spike in tritium measurements of environmental water samples by the 3He‐ingrowth method

Abstract: Dear Editor,Using an ultrapure 4 He spike in tritium measurements of environmental water samples by the 3 He-ingrowth method The tritium ( 3 H or T, half-life 12.32 years 1 ) concentrations of environmental water samples have already decreased below the level that can be accurately measured by conventional liquid scintillation or proportional counting techniques, even if electrolytic enrichment is used prior to the measurements. [2][3][4] In addition, when the precipitation infiltrates under the soil or ocean … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
30
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 55 publications
(30 citation statements)
references
References 17 publications
0
30
0
Order By: Relevance
“…Tritium was then precisely analyzed in seawater samples using the 3 He in-growth method (Palcsu et al, 2010).…”
Section: Tritium Analysismentioning
confidence: 99%
“…Tritium was then precisely analyzed in seawater samples using the 3 He in-growth method (Palcsu et al, 2010).…”
Section: Tritium Analysismentioning
confidence: 99%
“…The first samples for groundwater age estimation based on the tritium ( 3 H) content of water were also collected from the end of December 2013. Water samples for tritium have been analyzed using the 3He-ingrowth method (Palcsu et al 2010). Due to the principle of the method, the samples had to be stored for a couple of months so that 3 He is produced from the tritium decay.…”
Section: Methodsmentioning
confidence: 99%
“…All samples were then measured via LSC, with some also subjected to 3 He ingrowth method because this method is suitable for the measurement of very low tritium concentrations (Palcsu et al, 2010). As can be seen from Table 2, sample values obtained using the 3 He ingrowth technique correspond well with their LSC counterparts and as a result it can be stated that the low values produced with the latter method are valid, despite the large uncertainty and high detection limit.…”
Section: Rainwater Samples Affected By Tritium Released From the Plantmentioning
confidence: 95%
“…As a result, helium partial pressures achieved in the mass spectrometer were comparable to ones those are measured during calibration, using well known air aliquots. The overall precision of the tritium measurements was better than 2.4% above 0.1 Bq l À1 (Palcsu et al, 2010).…”
Section: Tritium Measurement Techniquesmentioning
confidence: 97%
See 1 more Smart Citation