2022
DOI: 10.3389/fnhum.2022.838187
|View full text |Cite
|
Sign up to set email alerts
|

Using Remotely Supervised At-Home TES for Enhancing Mental Resilience

Abstract: We are in the midst of a mental health crisis with major depressive disorder being the most prevalent among mental health disorders and up to 30% of patients not responding to first-line treatments. Noninvasive Brain Stimulation (NIBS) techniques have proven to be effective in treating depression. However, there is a fundamental problem of scale. Currently, any type of NIBS treatment requires patients to repeatedly visit a clinic to receive brain stimulation by trained personnel. This is an often-insurmountabl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 46 publications
0
6
0
Order By: Relevance
“…The headset includes built-in safety features such as constant impedance control and current adjustment which automatically terminates the stimulation session if the electrode impedance exceeds 20 k (41, 43) resulting in a prompt in the app for the patient to adjust the headset and start a new session. To ensure correct dose control, the protocol for session duration and stimulation intensity was pre-programmed remotely in accordance with the parameters described below (see Section 2.6) and patients did not have access to these settings in the app (42). The PlatoWork tDCS headset is a fixed-montage clinical headset designed for home-administered use and does not require manual electrode measurement or fixation, as shown in Figure 1.…”
Section: Tdcs Hardware and Softwarementioning
confidence: 99%
See 4 more Smart Citations
“…The headset includes built-in safety features such as constant impedance control and current adjustment which automatically terminates the stimulation session if the electrode impedance exceeds 20 k (41, 43) resulting in a prompt in the app for the patient to adjust the headset and start a new session. To ensure correct dose control, the protocol for session duration and stimulation intensity was pre-programmed remotely in accordance with the parameters described below (see Section 2.6) and patients did not have access to these settings in the app (42). The PlatoWork tDCS headset is a fixed-montage clinical headset designed for home-administered use and does not require manual electrode measurement or fixation, as shown in Figure 1.…”
Section: Tdcs Hardware and Softwarementioning
confidence: 99%
“…Finally, we recommend the use of expert ratings such as the Hamilton Depression Rating Scale or the Montgomery-Åsberg Depression Rating Scale instead of or in addition to the self-reported BDI questionnaire, which we had to select due to COVID-19 restrictions on in-person gatherings. Looking into the future, tDCS could even be integrated with data from other wearables and self-report measures, to predict relapses of depression and remotely initiate maintenance treatment (28,42,60).…”
Section: Figurementioning
confidence: 99%
See 3 more Smart Citations