“…This involved performing a sensitivity analysis (Morris method and FAST) on the effect of 24 variables, including building height, length, width, rotation, view of the ground, ground reflectivity, insulation thickness, glazing ratio, weather parameters, setpoint temperature, ventilation rates, and variables relating to occupancy and the building environment, on yearly heating loads, heating load per m 3 , heating power, and summer comfort. Other researchers (Samaan et al, 2018) employed a holistic approach that involved conducting different types of sensitivity analysis and uncertainty analysis.…”