2009
DOI: 10.1021/ar8002738
|View full text |Cite
|
Sign up to set email alerts
|

Using Two Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Contrast Agents for Molecular Imaging Studies

Abstract: CONSPECTUS Responsive magnetic resonance imaging (MRI) contrast agents can change MR image contrast in response to a molecular biomarker. Quantitative detection of the biomarker requires an accounting of the other effects that may alter MR image contrast, such as a change in the agent’s concentration, magnetic field variations, and hardware sensitivity profiles. A second unresponsive MRI contrast agent may serve as an “internal control” to isolate the detection of the molecular biomarker. Chemical exchange sat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
120
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
9
1

Relationship

3
7

Authors

Journals

citations
Cited by 102 publications
(123 citation statements)
references
References 28 publications
3
120
0
Order By: Relevance
“…6) (16). Even at a low concentration of 3.125 mM, the salicylic acid generated a 8.6% CEST signal and the aryl amide generated a 4.4% CEST signal.…”
Section: Resultsmentioning
confidence: 99%
“…6) (16). Even at a low concentration of 3.125 mM, the salicylic acid generated a 8.6% CEST signal and the aryl amide generated a 4.4% CEST signal.…”
Section: Resultsmentioning
confidence: 99%
“…42 The advent of the chemical exchange saturation transfer technique (CEST) has also brought a new dimension to resonance magnetic bioanalyses. 43,44 However, optical bioprobes are gaining momentum because when appropriate wavelengths are used their penetration depth may be substantial, allowing the detection of analytes and biomarkers in cells and tissues which are not detectable by other techniques. 3,45 The contribution of lanthanides to these aspects started more than 30 years ago with luminescent time-resolved immunoassays and is now omnipresent, judging by the impressive number of papers devoted to this type of research as well as of review articles.…”
Section: Lanthanide Luminescence In Biosciencesmentioning
confidence: 99%
“…Because the labile proton concentration has to be independently determined in order to derive pH, the conventional CEST imaging only provides pH-weighted information (Sun, 2010b; Zu et al , 2012; Sun et al , 2013b). To address this limitation, ratiometric CEST MRI has been proposed that normalizes the confounding concentration effect for simplifying pH measurement (Ward and Balaban, 2000; Ali et al , 2009; Liu et al , 2012). A particularly interesting ratiometric MRI agent is iopamidol, approved by food and drug administration (FDA) as a X-Ray contrast agent since 1980s, which has been recently shown capable of imaging renal pH (Longo et al , 2012; Longo et al , 2011; Aime et al , 2005).…”
Section: Introductionmentioning
confidence: 99%