2007 IEEE International Workshop on Imaging Systems and Techniques 2007
DOI: 10.1109/ist.2007.379557
|View full text |Cite
|
Sign up to set email alerts
|

Using two line scanning based spectral cameras simultaneously in one measurement process to create wider spectral area from the measured target

Abstract: In this paper; we describe one method how we can combine two different line scanning based spectral cameras, visible and infrared, to one measurement process and how we can automatically combine their different spectral areas to one wide area from 400 nm to 1700 nm. Proposed method has been used in scientific projects and we present two practical applications where this system is used and what benefits we get from it. Main part of this study is that how we can make more effective measurement process by using t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2008
2008
2013
2013

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 8 publications
0
1
0
Order By: Relevance
“…This device [1] can be a mechanical rotating wheel holding various filters [5], but we can also use a tunable filter, which can be a liquid crystal tunable filter [1,3] or an acoustic optic tunable filter [6]; this permits one to select a transmittance mode for each image taken and avoids the problems of rotating wheels regarding alignment and commuting time between different filters. Other possibilities exist that use linear scanning spectral cameras [7] for example. All these multispectral systems are really useful if we want to obtain spectral estimations with similar quality to that of the measurements obtained from a spectroradiometer, but they suffer from some technical drawbacks and costs that make them disadvantageous compared to a customer CCD camera, for example.…”
Section: Introductionmentioning
confidence: 99%
“…This device [1] can be a mechanical rotating wheel holding various filters [5], but we can also use a tunable filter, which can be a liquid crystal tunable filter [1,3] or an acoustic optic tunable filter [6]; this permits one to select a transmittance mode for each image taken and avoids the problems of rotating wheels regarding alignment and commuting time between different filters. Other possibilities exist that use linear scanning spectral cameras [7] for example. All these multispectral systems are really useful if we want to obtain spectral estimations with similar quality to that of the measurements obtained from a spectroradiometer, but they suffer from some technical drawbacks and costs that make them disadvantageous compared to a customer CCD camera, for example.…”
Section: Introductionmentioning
confidence: 99%