1999
DOI: 10.1016/s0021-9673(99)00257-5
|View full text |Cite
|
Sign up to set email alerts
|

Utility of isotachophoresis–capillary zone electrophoresis, mass spectrometry and high-performance size-exclusion chromatography for monitoring of interleukin-6 dimer formation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2000
2000
2015
2015

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(13 citation statements)
references
References 18 publications
0
13
0
Order By: Relevance
“…Application of hydrodynamic counterflow together with ITP technique made the complete length of capillary available for the separation step and resulted in the reduction of the LOQ of the method to the concentration range of 10 −8 M . One year later, Gysler and colleagues applied an ITP‐CZE method to monitor dimmer formation as a physical instability of rhIL‐6. The high sensitivity of the developed method owing to the application of ITP technique made it useful to separate monomer and dimmer forms of rhIL‐6.…”
Section: Ce‐based Methods Applied In the Quality Control Of Biopharmamentioning
confidence: 99%
See 1 more Smart Citation
“…Application of hydrodynamic counterflow together with ITP technique made the complete length of capillary available for the separation step and resulted in the reduction of the LOQ of the method to the concentration range of 10 −8 M . One year later, Gysler and colleagues applied an ITP‐CZE method to monitor dimmer formation as a physical instability of rhIL‐6. The high sensitivity of the developed method owing to the application of ITP technique made it useful to separate monomer and dimmer forms of rhIL‐6.…”
Section: Ce‐based Methods Applied In the Quality Control Of Biopharmamentioning
confidence: 99%
“…Gysler and co‐workers used a CZE‐ESI‐MS method to gain detailed information about the formation of dimmer complexes of rhIL‐6 under elevated temperature. Xin et al described the usefulness of a home‐built CE‐ESI‐ion cyclotron resonance‐MS instrument for the separation and structural identification of three peptides, including angiotensin III, octreotide, and elastin chemotactic, in a mixture.…”
Section: Ce‐based Methods Applied In the Quality Control Of Biopharmamentioning
confidence: 99%
“…Gysler et al [88] investigated the utility of ITP-CZE and high performance size-exclusion chromatography (HPSEC) to analyse dimeric and monomeric rhIL-6. Dimer formation was evaluated over a wide range of pH and temperature.…”
Section: Formulation Studiesmentioning
confidence: 99%
“…ITP preconcentration with hydrodynamic counterflow was used to enhance the detectability of amitriptyline and metoprolol in CZE (LE = BGE: 10 mM NaOH; TE: 6.1 mM tetrapentylammonium hydroxide, both adjusted to pH 2.75 with phosphoric acid) [95], to determine trace concentrations of recombinant human interleukin-3, recombinant human IL-6 and various basic model proteins (LE = BGE: 20 mM triethylamine (TEA) adjusted to pH 4.2 with acetic acid; TE: 20 mM b-alanine adjusted to pH 4.5 with acetic acid) [96], to monitor the formation of the interleukin-6 dimer (LE = BGE: 20 mM ammonium acetate adjusted to pH 4.2 with acetic acid; TE: 10 mM acetic acid) [97], to characterize recombinant cytokine fragments [98] and to preconcentrate a new cholinesterase inhibitor (NXX-066) prior to CZE analysis with LIF detection (LE = BGE: 10 mM NaOH adjusted to pH 2.72 with phosphoric acid; TE: 6.13 mM tetrahexylammonium chloride adjusted to pH 2.72 with phosphoric acid, 37,5% v/v methanol) [99]. The column coupling technique is being used for a long time to enhance the selectivity and sensitivity of ITP by combining two different ITP electrolyte systems.…”
Section: Transient Itp and Combined Techniquesmentioning
confidence: 99%