The diagnostic accuracy of myeloperoxidase (MPO) in pleural fluid, for differentiating between complicated and noncomplicated parapneumonic pleural effusions (PPE) evaluated prospectively.Seventy patients aged w18 yrs with PPE (36 complicated and 34 noncomplicated) were studied after admission to a tertiary referral teaching hospital. MPO concentration was measured in plasma and pleural fluid using a double-antibody competitive radioimmunoassay.The concentrations of MPO in complicated and noncomplicated PPE were compared using a Mann-Whitney U-test and multiple logistic regression models were used to predict the odds that an effusion was complicated. MPO pleural-fluid concentrations were significantly higher in complicated than in noncomplicated PPE. After excluding purulent effusions, pleural-fluid MPO was the marker that best differentiated between the two types of PPE: the area under the receiver operating characteristic curve was 0.912, the sensitivity was 87.5% and the specificity was 85.1% at a cut-point limit of 3.000 mg?L -1 . The authors concluded that the concentration of pleural-fluid myeloperoxidase helps to differentiate between nonpurulent complicated and noncomplicated parapneumonic pleural effusions.