Anais De XXXVIII Simpósio Brasileiro De Telecomunicações E Processamento De Sinais 2020
DOI: 10.14209/sbrt.2020.1570661619
|View full text |Cite
|
Sign up to set email alerts
|

Utilization of Low-Cost Pulse Coherent Radar for Physiological Assessment in Vehicle Interior

Abstract: Contactless human monitoring and radar have been a discussion topic in vehicular technology. This technology applied to interior monitoring may open new opportunities for assistance systems that provide information about the passenger's health condition. This paper characterizes the usage of a low-cost single radio-frequency pulse radar as a mean to assess driver's respiration and heart rate inside a vehicle. Real data acquisition was performed and the accuracy of the radar evaluated against a ground-truth (EC… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…It can be seen in Table I that a large number of recent works focused on measuring BR and HR accurately. In [60]- [64], [69], [228], the authors used different methods to reach this objective. When it comes to pulmonary diseases, respiratory rates may be used together with breathing patterns to both diagnose and track a person's health concerns.…”
Section: Referencementioning
confidence: 99%
See 2 more Smart Citations
“…It can be seen in Table I that a large number of recent works focused on measuring BR and HR accurately. In [60]- [64], [69], [228], the authors used different methods to reach this objective. When it comes to pulmonary diseases, respiratory rates may be used together with breathing patterns to both diagnose and track a person's health concerns.…”
Section: Referencementioning
confidence: 99%
“…Sensor place Frequency Ground truth Radar brand and/or package size [62] Mobile holder (right side of steering wheel) 60 Air-flow, Temperature sensor XM132 (25×20 mm) [65], [69] In front of the chest of the main subject 60 ECG XM112 [71] On the steering wheel 4.3 Edan iM50 Not specified [78] Rearview mirror 7.25 A USB pressing button to count breaths as a ground truth X2M200 (50×70 mm) [90] The upper left of the windshield 7.5 Pulse oximetry X4M300 (50×70 mm) [89] In front of the chest of the main subject 77 Pulse oximetry Not specified [82] Under the steering wheel 6.8…”
Section: Referencementioning
confidence: 99%
See 1 more Smart Citation