Background: simple, sensitive, free of organic solvents, kinetic spectrophotometric method has been developed for the determination of Clindamycin Hydrochloride, both in pure form and Capsules. Method used is based on reaction of Clindamycin with potassium iodide and potassium iodate in aqueous medium at (25 ±2 °c) to produce yellow colored tri iodide ions (I3-). the reaction is followed spectrophotometrically by measuring the absorbance at 350 nm wavelength during 40 minutes. Results: the effects of analytical parameters on reported kinetic methods were investigated. Under the optimized conditions, the initial rate and fixed time (at 10 min) methods were used for constructing the calibration graphs. The graphs were linear in concentration ranges 1-20 μg.ml-1 with limit of detection of 0.12 and 0.22 μg ml-1for the initial rate and fixed time methods, respectively. The results were satisfactory and the analytical performance for both methods was validated. Conclusion: The proposed methods have been applied to determine the components in capsules with an average recovery of 98.25% to 102.00% and the results are in good agreement with those found by the reference method.