2011
DOI: 10.1115/1.4003080
|View full text |Cite
|
Sign up to set email alerts
|

Validation and Analysis of Numerical Results for a Varying Aspect Ratio Two-Pass Internal Cooling Channel

Abstract: Numerical results for an internal ribbed cooling channel including a 180 deg bend with a 2:1 inlet and a 1:1 aspect ratio outlet channel were validated against experimental results in terms of spatially resolved heat transfer distributions, pressure losses, and velocity distributions. The numerical domain consisted of one rib segment in the inlet channel and three ribs segments in the outlet channel to reduce the overall numerical effort and allow for an extensive parametric study. The results showed good agre… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
28
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
6
3

Relationship

2
7

Authors

Journals

citations
Cited by 82 publications
(30 citation statements)
references
References 12 publications
2
28
0
Order By: Relevance
“…It is clear to see that the Re k-ε model is among one of the three models that are relatively closer to the experimental data. This matches well with Shevchuk et al 23 and Hassan et al 24 Three types of wall-function methods are adopted in the near-wall region, and the Non-equilibrium wall function is suggested to be as the best one, as shown in Fig. 11.…”
Section: Grids and Computational Methodssupporting
confidence: 71%
“…It is clear to see that the Re k-ε model is among one of the three models that are relatively closer to the experimental data. This matches well with Shevchuk et al 23 and Hassan et al 24 Three types of wall-function methods are adopted in the near-wall region, and the Non-equilibrium wall function is suggested to be as the best one, as shown in Fig. 11.…”
Section: Grids and Computational Methodssupporting
confidence: 71%
“…The structured and hybrid grids provide the same accuracy in simulations [29] and because of the several rounded shapes constituent the GHE, the hybrid grid is more suitable and it was adopted. Grid-independency studies with three grids sized from a coarse mesh of 357,642 cells to a finer mesh of 398,454 cells lead to the final conclusion that the average grid size for providing the necessary near-wall grid resolution and grid-independency for the GHEs studied fell within the 369,833 cells.…”
Section: Governing Equationsmentioning
confidence: 99%
“…5, the model is consisted of two face sheets and pyramidal lattice core with 4 Â 4 unit cells along the two in-plane directions. Mesh sensitivity study is a necessary analysis to ensure that the numerical simulation results are grid-independent [22,23]. The geometrical model was meshed through the preprocessor of Abaqus.…”
Section: Lattice Sandwich Panel Modelmentioning
confidence: 99%