Validation and quantitative analysis of cadmium, chromium, copper, nickel, and lead in snake fruit by Inductively Coupled Plasma-Atomic Emission Spectroscopy

Abstract: Snake fruit or known as Salak is one of the favourite fruits and is consumed not only in Indonesia but also in the worldwide. The fruit may be contaminated with heavy toxic metals such as cadmium (Cd), chromium (Cr), copper (Cu), nickel (Ni), and lead (Pb). The purpose of this study was to validate inductively coupled plasma-atomic emission spectroscopy (ICP-AES) for determination of Cd, Cr, Cu, Ni, and Pb in snake fruit. ICP-AES was validated by determining several validation parameters which included lineari… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 4 publications
0
4
0
Order By: Relevance
“…The mean percent recoveries for the studied metals in the spiked sample ranged between 89.36 and 97.70%, which falls within the acceptable recovery value range of 80-120% for metal analysis [28]. The % RSD for precision determination ranged from 0.79 to 4.65% (Table 4), which was under the acceptable limits of ≤ 11% [39]. The coefficient of variation (CV) was further used to monitor precision.…”
Section: Methods Validationmentioning
confidence: 77%
“…The mean percent recoveries for the studied metals in the spiked sample ranged between 89.36 and 97.70%, which falls within the acceptable recovery value range of 80-120% for metal analysis [28]. The % RSD for precision determination ranged from 0.79 to 4.65% (Table 4), which was under the acceptable limits of ≤ 11% [39]. The coefficient of variation (CV) was further used to monitor precision.…”
Section: Methods Validationmentioning
confidence: 77%
“…Measurement of the relative standard deviation of the data was helpful in ICP‐MS assessment and understanding the precision of the analytical procedure. 25 Fourteen analytes and 5 liquid internal standards were obtained for the acquisition of the data (Table 3 ). All the analytes were selected based on the detected elements in SEM‐EDX analysis.…”
Section: Resultsmentioning
confidence: 99%
“…An ICPE typically involves some components like sample introduction system, ICPE torch, high frequency generator, transfer optics and spectrometer, and computer interface. [18][19][20][21] The current paper aimed to detect and calculate the concentrations of macro, micro, toxic, and radioactive metals minerals before and after exposure to the selected sample to the normal sunlight which was taken from Al-Mogran Station in the Blue Nile River at Khartoum State, Sudan at the end of the fall season 2019.…”
Section: Introductionmentioning