2010
DOI: 10.1177/193229681000400521
|View full text |Cite
|
Sign up to set email alerts
|

Validation of a Deconvolution Procedure (AutoDecon) for Identification and Characterization of Fasting Insulin Secretory Bursts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2013
2013
2017
2017

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 32 publications
0
4
0
Order By: Relevance
“…Across testing days, there were no significant differences in body weight in any of the subjects. According to self-report dietary logs and physical activity questionnaires, subjects consumed meals an average of 4.7±0.38 times/day, and participated in walking activity 3.3±0.57 times/wk at a Borg RPE (620) level of 13.4±0.5.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Across testing days, there were no significant differences in body weight in any of the subjects. According to self-report dietary logs and physical activity questionnaires, subjects consumed meals an average of 4.7±0.38 times/day, and participated in walking activity 3.3±0.57 times/wk at a Borg RPE (620) level of 13.4±0.5.…”
Section: Resultsmentioning
confidence: 99%
“…The c-peptide pulse profile was analyzed using a multi-parameter deconvolution technique (AutoDecon, Pulse_XP software; University of Virginia) designed to derive quantitative estimates of attributes of c-peptide secretory pulses and half-life from measured c-peptide concentrations (19, 20). Basal secretion was estimated for each condition, and assumed not to change during the exercise days (19).…”
Section: Methodsmentioning
confidence: 99%
“…Insulin secretion was determined using the C-peptide data. A pulse profile was analysed using a multi-parameter deconvolution technique (AutoDecon, Pulse_XP software; University of Virginia) that derives quantitative estimates of attributes of C-peptide secretory pulses and half-life from measured C-peptide concentrations ( 22 , 23 ) . A Gaussian distribution of secretory rate was assumed using the serum C-peptide concentration value and it was assumed to match insulin concentration at a 1:1 ratio.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…The Gaussian shaped events that are fitted in deconvolution analysis have the advantage to be applicable on a wide range of pulsatile compounds [ 31 , 32 ]. However, this generalization inherently brings the disadvantage that no mechanistic information of the biological regulation of the compound is incorporated in the structural model.…”
Section: Discussionmentioning
confidence: 99%