2021
DOI: 10.3390/s21217342
|View full text |Cite
|
Sign up to set email alerts
|

Validation of a Hybrid Exoskeleton for Upper Limb Rehabilitation. A Preliminary Study

Abstract: Recovery of therapeutic or functional ambulatory capacity in patients with rotator cuff injury is a primary goal of rehabilitation. Wearable powered exoskeletons allow patients to perform repetitive practice with large movements to maximize recovery, even immediately after the acute event. The aim of this paper is to describe the usability, acceptability and acceptance of a hybrid exoskeleton for upper-limb passive rehabilitation using the System Usability Scale (SUS) questionnaire. This equipment, called ExoF… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 26 publications
0
5
0
Order By: Relevance
“…As shown in Figure 3 , the majority of articles focusing on the most used questionnaires for evaluating the usability of robots and smart wearables were published in 2020 ( n = 11), 22 29 , 52 54 2021 ( n = 9), 1,0– 34 , 55 57 and 2022 ( n = 10), 35 41 , 58 60 respectively (More details in Table 2 ).…”
Section: Resultsmentioning
confidence: 99%
“…As shown in Figure 3 , the majority of articles focusing on the most used questionnaires for evaluating the usability of robots and smart wearables were published in 2020 ( n = 11), 22 29 , 52 54 2021 ( n = 9), 1,0– 34 , 55 57 and 2022 ( n = 10), 35 41 , 58 60 respectively (More details in Table 2 ).…”
Section: Resultsmentioning
confidence: 99%
“…The following development is focused on the design of the algorithm for a single DC motor. For simulation, the chosen parameters are the ones of a Maxon DCX22S GB KL 48V, which is the model that authors use for their exoskeletons/exosuits in [5] and [22]. Motor parameters can be found in Table 1 and have been extracted from the datasheet.…”
Section: Algorithm Design and Analysismentioning
confidence: 99%
“…The algorithm has been implemented over the cable-driven rehabilitation upper-limb exoskeleton ExoFlex [5]. The objective of this experiment is to validate the current limitation method developed in this work in a real application, in which the load over the motor can vary arbitrarily since there exists human-robot interaction.…”
Section: B Exoskeleton Validation Testsmentioning
confidence: 99%
See 1 more Smart Citation
“…Preliminary evidence of the acceptance and usability by both patients and clinicians are very promising, obtaining an average score of 80.71 in the SUS test, as well as good results in a questionnaire that evaluates the clinicians' perceived usability of ExoFlex. This study is the modified compilation of publication [216].…”
Section: Preamble Of the Studymentioning
confidence: 99%