Validation of a low-dose hybrid RSA and fluoroscopy technique: Determination of accuracy, bias and precision

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(18 citation statements)
references
References 15 publications
0
18
0
Order By: Relevance
“…The exposure parameters were estimated from previous phantom studies (Allen et al, 2004;Ioppolo et al, 2007;Ma¨kinen et al, 2004;Ö nsten et al, 2001) and selected as 70 kVp at 16 mA s for both the new cage and the uniplanar cage, and 50 kVp at 4 mA s for the biplanar cage. The radiographic examinations were performed in a dedicated RSA lab with two ceiling-mounted X-ray units (Proteus XR/a, GE Medical Systems, Milwaukee, WI, USA) and digital images were acquired by a computed radiography digital X-ray system (Capsula X CR, FujiFilm, Tokyo, Japan), which provides 3520 Â 4280 image matrix for a 35 Â 43 cm cassette and 2364 Â 2964 matrix for a 24 Â 30 cm cassette.…”
Section: Phantom Validationmentioning
confidence: 99%
“…The exposure parameters were estimated from previous phantom studies (Allen et al, 2004;Ioppolo et al, 2007;Ma¨kinen et al, 2004;Ö nsten et al, 2001) and selected as 70 kVp at 16 mA s for both the new cage and the uniplanar cage, and 50 kVp at 4 mA s for the biplanar cage. The radiographic examinations were performed in a dedicated RSA lab with two ceiling-mounted X-ray units (Proteus XR/a, GE Medical Systems, Milwaukee, WI, USA) and digital images were acquired by a computed radiography digital X-ray system (Capsula X CR, FujiFilm, Tokyo, Japan), which provides 3520 Â 4280 image matrix for a 35 Â 43 cm cassette and 2364 Â 2964 matrix for a 24 Â 30 cm cassette.…”
Section: Phantom Validationmentioning
confidence: 99%
“…It has the potential for accuracy surpassing that of optical tracking methods and approaching that of RSA with digital radiography. Work has been done previously to assess the accuracy, bias, and precision of RSA systems (Tashman and Anderst, 2003;Li et al, 2004;Ioppolo et al, 2007;Koning et al, 2007). Furthermore, one study used fRSA as the gold standard to quantify the accuracy of a skin-mounted tracking system .…”
Section: Introductionmentioning
confidence: 99%
“…Radiostereometric analysis (RSA) may be a way forward. RSA involves implantation of tantalum markers to analyze implant and joint micromotion and has been shown to be accurate [4,9,12,16,21]. Further work is needed to evaluate this technology for use in TDR ROM measurements.…”
Section: Discussionmentioning
confidence: 99%