2020
DOI: 10.1002/jms.4634
|View full text |Cite
|
Sign up to set email alerts
|

Validation of a rapid ultra‐high‐performance liquid chromatography–tandem mass spectrometry method for quantification of chlorogenic acids in roasted coffee

Abstract: Chlorogenic acids (CGAs) are a large class of esters formed between quinic acid and hydroxycinnamic acids. They are present in coffee as a complex mixture of positional and geometric isomers, where caffeoylquinic acids (CQAs) are the most abundant, followed by dicaffeoylquinic acids (diCQAs), feruloylquinic acids (FQAs), and p-coumaroylquinic acids (p-CoQAs). The aim of this work is to develop a new reliable and fast liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous identificati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 38 publications
0
4
0
Order By: Relevance
“…Quantitative analysis was performed; the concentration of each SiQA isomer in the samples was calculated as 5‐CQA equivalent using an external standard method through calibration curves. The method was validated in terms of specificity, linearity, concentration range, accuracy, and repeatability according to the criteria specified in EU Commission Decision 2002/675/EC following the procedure previously published 25 . To evaluate the linearity of the method, six standard solutions approximately equally spaced with concentrations ranging from 0.068 to 6.8 μg/mL of 5‐CQA were analyzed in duplicate on three different days.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Quantitative analysis was performed; the concentration of each SiQA isomer in the samples was calculated as 5‐CQA equivalent using an external standard method through calibration curves. The method was validated in terms of specificity, linearity, concentration range, accuracy, and repeatability according to the criteria specified in EU Commission Decision 2002/675/EC following the procedure previously published 25 . To evaluate the linearity of the method, six standard solutions approximately equally spaced with concentrations ranging from 0.068 to 6.8 μg/mL of 5‐CQA were analyzed in duplicate on three different days.…”
Section: Resultsmentioning
confidence: 99%
“…CEs were optimized to maximize the transition signals (precursor ion to product ion). The method was validated in terms of specificity, linearity, concentration range, LOD, limit of quantification (LOQ), precision, and trueness following the guidelines previously reported 25 . All data were processed using MultiQuant 3.0.2. software (Sciex, Framingham, MA, USA), and statistical analysis were carried out using XLSTAT 2018 (Microsoft, Sunnyvale, California USA).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations